Ê Select the Server Mgmt menu.
Ê Under Boot Watchdog set the Action setting to Continue.
Ê Save your changes and exit the BIOS.
I
For more information on BIOS settings, see the corresponding BIOS
Setup Utility reference manual.
Disabling the boot watchdog using the iRMC web interface
Ê Log in to the ServerView iRMC web interface.
Ê Select the Settings menu.
Ê Open the Server Management page.
Ê In the Boot Watchdog group, check the Enable Boot Watchdog option.
The Enable Boot Watchdog option must be selected.
Ê Select Continue from the Watchdog Action list.
Ê Click Apply for the changes to take effect.
I
For more information on iRMC settings, see the iRMC user guides.
5.1.3
Removing backup and optical disk media
Ê Ask the system administrator to eject all remaining backup or optical media
from the backup or optical disk drive before removing it from the server.
Ê If the backup media cannot be ejected by conventional means, and it is
mandatory that the cartridge be removed prior to returning the drive for
repair or disposing it, a manual tape extraction needs to be performed.
For more information on "forcible" tape ejection, see the "Tape Facts" pages
available to Fujitsu service partners from the following https address:
https://partners.ts.fujitsu.com/com/service/ps/Servers/PRIMERGY/Pages/
TapeFacts.aspx
For Japan:
Please contact Fujitsu support, if "forcible" tape ejection is necessary.
I
Fujitsu does not assume responsibility for any damage to the tape
drive, the data cartridge/tape or for the loss of any data resulting from
manual tape extraction procedures.
TX1330 M4
Upgrade and Maintenance Manual
Basic software procedures