142 Parameters
No.
Name/Value
03.02
Panel reference
remote
-100000.00...
100000.00 rpm, Hz
or %
03.05
FB A reference 1
-100000.00...
100000.00
03.06
FB A reference 2
-100000.00...
100000.00
03.09
EFB reference 1
-30000.00...
30000.00
03.10
EFB reference 2
-30000.00...
30000.00
04

04 Warnings and faults

04.01
Tripping fault
0000h...FFFFh
04.02
Active fault 2
0000h...FFFFh
04.03
Active fault 3
0000h...FFFFh
04.06
Active warning 1
0000h...FFFFh
04.07
Active warning 2
0000h...FFFFh
04.08
Active warning 3
0000h...FFFFh
04.11
Latest fault
0000h...FFFFh
04.12
2nd latest fault
0000h...FFFFh
04.13
3rd latest fault
0000h...FFFFh
Description
Reference 2 given from the control panel or PC tool.
Control panel or PC tool reference.
Reference 1 received through fieldbus adapter A.
See also chapter
Fieldbus control through a fieldbus adapter
(page 405).
Reference 1 from fieldbus adapter A.
Reference 2 received through fieldbus adapter A.
Reference 2 from fieldbus adapter A.
Scaled reference 1 received through the embedded fieldbus
interface.
Scaled reference 1 received through the embedded fieldbus
interface.
Scaled reference 2 received through the embedded fieldbus
interface.
Scaled reference 2 received through the embedded fieldbus
interface.
Information on warnings and faults that occurred last.
For explanations of individual warning and fault codes, see
chapter
Fault
tracing.
All parameters in this group are read-only unless otherwise
noted.
Code of the 1st active fault (the fault that caused the current
trip).
1st active fault.
Code of the 2nd active fault.
2nd active fault.
Code of the 3rd active fault.
3rd active fault.
Code of the 1st active warning.
1st active warning.
Code of the 2nd active warning.
2nd active warning.
Code of the 3rd active warning.
3rd active warning.
Code of the 1st stored (non-active) fault.
1st stored fault.
Code of the 2nd stored (non-active) fault.
2nd stored fault.
Code of the 3rd stored (non-active) fault.
3rd stored fault.
Def/FbEq16
-
1 = 10 unit
-
1 = 10
-
1 = 10
1 = 10
1 = 10
1 = 10
1 = 10
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1