362 Fault tracing
Code
Warning / Aux. code
(hex)
A4B0
Excess temperature
A4B1
Excess temperature
difference
A4F6
IGBT temperature
A580
PU communication
A5A0
Safe torque off
Programmable warning:
31.22 STO indication
run/stop
A5EA
Measurement circuit
temperature
A5EB
PU board powerfail
A5EC
PU communication
internal
A5ED
Measurement circuit
ADC
A5EE
Measurement circuit
DFF
A5EF
PU state feedback
A5F0
Charging feedback
A6A4
Motor nominal value
A6A5
No motor data
A6A6
Voltage category
unselected
Cause
Power unit module
temperature is excessive.
High temperature difference
between the IGBTs of different
phases.
Drive IGBT temperature is
excessive.
Communication errors
detected between the drive
control unit and the power unit.
Safe torque off function is
active, ie safety circuit signal(s)
connected to connector STO is
lost.
Problem with internal
temperature measurement of
the drive.
Power unit power supply
failure.
Communication errors
detected between the drive
control unit and the power unit.
Measurement circuit fault.
Measurement circuit fault.
State feedback from output
phases does not match control
signals.
Charging feedback signal
missing.
The motor parameters are set
incorrectly.
The drive is not dimensioned
correctly.
Parameters in group 99 have
not been set.
The voltage category has not
been defined.
What to do
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against drive power.
Check the motor cabling.
Check cooling of drive module(s).
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against drive power.
Check the connections between the drive
control unit and the power unit.
Check the value of parameter
Control board
supply.
Check safety circuit connections. For
more information, chapter The Safe
torque off function in the Hardware
manual of the drive and description of
parameter
31.22 STO indication run/stop
(page 231).
Check the value of parameter
Control board
supply.
Contact your local ABB representative.
Contact your local ABB representative.
Check the connections between the drive
control unit and the power unit.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Check the feedback signal coming from
the charging system.
Check the settings of the motor
configuration parameters in group 99.
Check that the drive is sized correctly for
the motor.
Check that all the required parameters in
group 99 have been set.
Note: It is normal for this warning to
appear during the start-up and continue
until the motor data is entered.
Set voltage category in parameter
Supply
voltage.
95.04
95.04
95.01