References - ABB ACS580 Firmware Manual

General purpose drives, standard control program
Hide thumbs Also See for ACS580:
Table of Contents

Advertisement

References

References are 16-bit words containing a sign bit and a 15-bit integer. A negative
reference (indicating reversed direction of rotation) is formed by calculating the two's
complement from the corresponding positive reference.
ABB drives can receive control information from multiple sources including analog
and digital inputs, the drive control panel and a fieldbus adapter module. In order to
have the drive controlled through the fieldbus, the module must be defined as the
source for control information such as reference. This is done using the source
selection parameters in groups
chain
and
28 Frequency reference
Debugging the network words
If parameter
50.12 FBA A debug mode
received from the fieldbus are displayed by
A reference
2.
Scaling of references
The references are scaled as defined by parameters 46.01...46.04; which scaling is
in use depends on the setting of
Fieldbus
The scaled references are shown by parameters
FB A reference
2.
Fieldbus control through a fieldbus adapter 409
22 Speed reference
chain.
is set to
50.04 FBA A ref1 type
46.01
(with speed reference)
20000
46.02
(with frequency reference)
46.03
(with torque reference)
10000
0
0
-(46.03) (with torque reference)
-10000
-(46.01) (with speed reference)
-20000
-(46.02) (with frequency reference)
selection,
Fast
or Normal, the references
50.14 FBA A reference 1
and
50.05 FBA A ref2
Drive
03.05 FB A reference 1
26 Torque reference
and
50.15 FBA
type.
and
03.06

Hide quick links: