Process Pid Set 2 - ABB ACS580 Firmware Manual

General purpose drives, standard control program
Hide thumbs Also See for ACS580:
Table of Contents

Advertisement

272 Parameters
No.
Name/Value
40.92
Setpoint data
storage
-327.68...327.67
41

41 Process PID set 2

41.08
Set 2 feedback 1
source
41.09
Set 2 feedback 2
source
41.10
Set 2 feedback
function
41.11
Set 2 feedback filter
time
41.16
Set 2 setpoint 1
source
41.17
Set 2 setpoint 2
source
41.18
Set 2 setpoint
function
41.19
Set 2 internal
setpoint sel1
41.20
Set 2 internal
setpoint sel2
41.21
Set 2 internal
setpoint 1
41.22
Set 2 internal
setpoint 2
41.23
Set 2 internal
setpoint 3
41.26
Set 2 setpoint min
41.27
Set 2 setpoint max
41.28
Set 2 setpoint
increase time
41.29
Set 2 setpoint
decrease time
41.30
Set 2 setpoint
freeze enable
Description
Storage parameter for receiving a process setpoint value eg.
through the embedded fieldbus interface.
The value can be sent to the drive as Modbus I/O data. Set
the target selection parameter of that particular data
(58.101...58.114)) to
Setpoint data
setpoint 1 source
(or
40.17 Set 1 setpoint 2
Setpoint data
storage.
Storage parameter for process setpoint.
A second set of parameter values for process PID control.
The selection between this set and first set (parameter group
40 Process PID set
1) is made by parameter
set1/set2
selection.
See also parameters 40.01...40.06, and the control chain
diagrams on pages
430
See parameter
40.08 Set 1 feedback 1
See parameter
40.09 Set 1 feedback 2
See parameter
40.10 Set 1 feedback
See parameter
40.11 Set 1 feedback filter
See parameter
40.16 Set 1 setpoint 1
See parameter
40.17 Set 1 setpoint 2
See parameter
40.18 Set 1 setpoint
See parameter
40.19 Set 1 internal setpoint
See parameter
40.20 Set 1 internal setpoint
See parameter
40.21 Set 1 internal setpoint
See parameter
40.22 Set 1 internal setpoint
See parameter
40.23 Set 1 internal setpoint
See parameter
40.26 Set 1 setpoint
See parameter
40.27 Set 1 setpoint
See parameter
40.28 Set 1 setpoint increase
See parameter
40.29 Set 1 setpoint decrease
See parameter
40.30 Set 1 setpoint freeze
storage. In
40.16 Set 1
source), select
40.57 PID
and 431.
source.
source.
function.
time.
source.
source.
function.
sel1.
sel2.
1.
2.
3.
min.
max.
time.
time.
enable.
Def/FbEq16
-
100 = 1
AI2 percent
Not selected
In1
0.000 s
AI1 percent
Not selected
In1
Not selected
Not selected
0.00 PID
customer
units
0.00 PID
customer
units
0.00 PID
customer
units
0.00
32767.00
0.0 s
0.0 s
Not selected