ABB ACS580 Firmware Manual page 260

General purpose drives, standard control program
Hide thumbs Also See for ACS580:
Table of Contents

Advertisement

256 Parameters
No.
Name/Value
Process PID out
Other
36.02
PVL filter time
0.00...120.00 s
36.06
AL2 signal source
36.07
AL2 signal scaling
0.00...32767.00
36.09
Reset loggers
Done
All
PVL
AL2
36.10
PVL peak value
-32768.00...
32767.00
36.11
PVL peak date
-
36.12
PVL peak time
-
36.13
PVL current at peak
-32768.00...
32767.00 A
36.14
PVL DC voltage at
peak
0.00...2000.00 V
36.15
PVL speed at peak
-30000.00...
30000.00 rpm
36.16
PVL reset date
-
36.17
PVL reset time
-
Description
40.01 Process PID output actual
Source selection (see
Terms and abbreviations
Peak value logger filtering time. See parameter
signal
source.
Peak value logger filtering time.
Selects the signal to be monitored by amplitude logger 2. The
signal is sampled at 200 ms intervals.
The results are displayed by parameters 36.40...36.49. Each
parameter represents an amplitude range, and shows what
portion of the samples fall within that range.
The signal value corresponding to 100% is defined by
parameter
36.07 AL2 signal
Amplitude logger 2 can be reset using parameter
loggers. The date and time of the last reset are stored into
parameters
36.50
and
36.51
For the selections, see parameter
Defines the signal value that corresponds to 100% amplitude. 100.00
Signal value corresponding to 100%.
Resets the peak value logger and/or amplitude logger 2.
(Amplitude logger 1 cannot be reset.)
Reset completed or not requested (normal operation).
Reset both the peak value logger and amplitude logger 2.
Reset the peak value logger.
Reset amplitude logger 2.
Peak value recorded by the peak value logger.
Peak value.
The date on which the peak value was recorded.
Peak occurrence date.
The time at which the peak value was recorded.
Peak occurrence time.
Motor current at the moment the peak value was recorded.
Motor current at peak.
Voltage in the intermediate DC circuit of the drive at the
moment the peak value was recorded.
DC voltage at peak.
Motor speed at the moment the peak value was recorded.
Motor speed at peak.
The date on which the peak value logger was last reset.
Last reset date of the peak value logger.
The time at which the peak value logger was last reset.
Last reset time of the peak value logger.
(page 261).
on page 136). -
36.01 PVL
scaling.
36.09 Reset
respectively.
36.01 PVL signal
Def/FbEq16
16
2.00 s
100 = 1 s
Motor torque
source.
1 = 1
Done
0
1
2
3
0.00
1 = 1
01.01.1980
-
00:00:00
-
0.00 A
1 = 1 A
0.00 V
10 = 1 V
0.00 rpm
See par.
46.01
01.01.1980
-
00:00:00
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF