No.
Name/Value
Frequency input
Control panel (ref
saved)
Control panel (ref
copied)
Other
28.12
Ext1 frequency ref2
28.13
Ext1 frequency
function
Ref1
Add (ref1 + ref2)
Sub (ref1 - ref2)
Mul (ref1 × ref2)
Min (ref1, ref2)
Max (ref1, ref2)
28.15
Ext2 frequency ref1
Zero
AI1 scaled
Description
11.38 Freq in 1 actual value
input).
Panel reference
(03.01 Panel
saved by the control system for the location where the control
returns is used as the reference.
Reference
Ext1 -> Ext2
Panel reference
(03.01 Panel
the previous control location is used as the reference when
the control location changes if the references for the two
locations are of the same type (eg
frequency/speed/torque/PID); otherwise, the actual signal is
used as the new reference.
Reference
Ext1 -> Ext2
Source selection (see
Terms and abbreviations
Selects Ext1 frequency reference source 2.
For the selections, and a diagram of reference source
selection, see parameter
Selects a mathematical function between the reference
sources selected by parameters
and
28.12 Ext1 frequency
frequency
ref1.
Signal selected by
28.11 Ext1 frequency ref1
frequency reference 1 as such (no function applied).
The sum of the reference sources is used as frequency
reference 1.
The subtraction
([28.11 Ext1 frequency
frequency
ref2]) of the reference sources is used as
frequency reference 1.
The multiplication of the reference sources is used as
frequency reference 1.
The smaller of the reference sources is used as frequency
reference 1.
The greater of the reference sources is used as frequency
reference 1.
Selects Ext2 frequency reference source 1.
Two signal sources can be defined by this parameter and
28.16 Ext2 frequency
ref2. A mathematical function
Ext2 frequency
function) applied to the two signals creates an
Ext2 reference. See diagram at
None.
12.12 AI1 scaled value
(see page 157).
(when DI6 is used as a frequency
reference, see page 141)
Ext1 reference
Ext2 reference
Active reference
Inactive reference
t
reference, see page 141) for
Ext1 reference
Ext2 reference
Active reference
Inactive reference
t
on page 136). -
28.11 Ext1 frequency
ref1.
28.11 Ext1 frequency ref1
ref2. See diagram at
28.11 Ext1
is used as
ref1] -
[28.12 Ext1
28.11 Ext1 frequency
Parameters 215
Def/FbEq16
17
18
19
Zero
Ref1
0
1
2
3
4
5
Zero
(28.17
ref1.
0
1

Hide quick links: