Code
Fault / Aux. code
(hex)
5093
Rating ID mismatch
5094
Measurement circuit
temperature
50A0
Fan
5681
PU communication
5682
Power unit lost
5690
PU communication
internal
5691
Measurement circuit
ADC
5692
PU board powerfail
5693
Measurement circuit
DFF
5696
PU state feedback
5697
Charging feedback
6181
FPGA version
incompatible
6306
FBA A mapping file
6481
Task overload
6487
Stack overflow
64A1
Internal file load
Cause
The hardware of the drive does
not match the information
stored in the memory. This
may occur eg. after a firmware
update.
Problem with internal
temperature measurement of
the drive.
Cooling fan stuck or
disconnected.
Communication errors
detected between the drive
control unit and the power unit.
Connection between the drive
control unit and the power unit
is lost.
Internal communication error.
Measurement circuit fault.
Power unit power supply
failure.
Measurement circuit fault.
State feedback from output
phases does not match control
signals.
Charging feedback signal
missing.
Firmware and FPGA versions
are incompatible.
Fieldbus adapter A mapping
file read error.
Internal fault.
Internal fault.
File read error.
Fault tracing 371
What to do
Cycle the power to the drive. You may
have to be repeat this.
Contact your local ABB representative.
Check fan operation and connection.
Replace fan if faulty.
Check the connection between the drive
control unit and the power unit.
Check the value of parameter
Control board
supply.
Check the connection between the
control unit and the power unit.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Check the feedback signal coming from
the charging system
Reboot the control unit (using parameter
96.08 Control board
boot) or by cycling
power. If the problem persists, contact
your local ABB representative
Contact your local ABB representative.
Reboot the control unit (using parameter
96.08 Control board
boot) or by cycling
power. If the problem persists, contact
your local ABB representative
Reboot the control unit (using parameter
96.08 Control board
boot) or by cycling
power. If the problem persists, contact
your local ABB representative
Reboot the control unit (using parameter
96.08 Control board
boot) or by cycling
power. If the problem persists, contact
your local ABB representative