ABB ACS580 Firmware Manual page 71

General purpose drives, standard control program
Hide thumbs Also See for ACS580:
Table of Contents

Advertisement

Terminal sizes:
R0...R3: 0.2...2.5 mm
0.14...1.5 mm
R5...R9: 0.14...2.5 mm
Tightening torques: 0.5...0.6 N·m (0.4 lbf·ft)
Notes:
1)
In scalar control (default): See Menu - Primary settings - Start, stop, reference - Constant
frequencies or parameter group
In vector control: See Menu - Primary settings - Start, stop, reference - Constant speeds
or parameter group
DI3 DI4
Scalar control (default)
0
0
Set frequency through AI1
1
0
28.26 Constant frequency 1
0
1
28.27 Constant frequency 2
1
1
28.28 Constant frequency 3
2)
In scalar control (default): See Menu - Primary settings - Ramps or parameter group
Frequency reference
In vector control: See Menu - Primary settings - Ramps or parameter group
reference
ramp.
DI5 Ramp
set
Scalar control (default)
0
1
28.72 Freq acceleration time 1
28.73 Freq deceleration time 1
1
2
28.74 Freq acceleration time 2
28.75 Freq deceleration time 2
3)
Ground the outer shield of the cable 360 degrees under the grounding clamp on the
grounding shelf for the control cables.
4)
Connected with jumpers at the factory.
5)
Note: Use shielded twisted-pair cables for digital signals.
Input signals
Analog speed/frequency reference (AI1)
Start motor forward (DI1)
Start motor in reverse (DI2)
Constant speed/frequency selection (DI3, DI4)
Ramp set (1 of 2) selection (DI5)
Run enable (DI6)
Output signals
Analog output AO1: Output frequency
Analog output AO2: Motor current
Relay output 1: Ready run
Relay output 2: Running
Relay output 3: Fault (-1)
2
(terminals +24V, DGND, DCOM, B+, A-)
2
(terminals DI, AI, AO, AGND, RO, STO)
2
(all terminals)
28 Frequency reference
22 Speed reference
selection.
chain.
chain.
Operation/Parameter
Vector control
Set speed through AI1
22.26 Constant speed 1
22.27 Constant speed 2
22.28 Constant speed 3
Parameters
Vector control
23.12 Acceleration time 1
23.13 Deceleration time 1
23.14 Acceleration time 2
23.15 Deceleration time 2
Control macros 67
28
23 Speed