No.
Name/Value
15.24
DO1 ON delay
Status of selected
source
RO status
t
=
15.24 DO1 ON delay
On
t
=
15.25 DO1 OFF delay
Off
0.0 ... 3000.0 s
15.25
DO1 OFF delay
0.0 ... 3000.0 s
15.32
Freq out 1 actual
value
0 ... 16000 Hz
15.33
Freq out 1 source
Not selected
Motor speed used
Output frequency
Motor current
Motor torque
DC voltage
Output power
Speed ref ramp in
Speed ref ramp out
Speed ref used
Torque ref used
Freq ref used
Process PID out
Other
Description
Defines the activation delay for relay output DO1 when
DO1 configuration
is set to
t
t
On
Off
Activation delay for DO1.
Defines the deactivation delay for relay output DO1 when
15.22 DO1 configuration
parameter
15.24 DO1 ON
Deactivation delay for DO1.
Displays the value of frequency output 1 at digital output DO1
when
15.22 DO1 configuration
This parameter is read-only.
Value of frequency output 1.
Selects a signal to be connected to digital output DO1 when
15.22 DO1 configuration
Alternatively, sets the output to excitation mode to feed a
constant current to a temperature sensor.
None.
01.01 Motor speed used
01.06 Output frequency
01.07 Motor current
(page 139).
01.10 Motor torque
(page 139).
01.11 DC voltage
(page 139).
01.14 Output power
(page 140).
23.01 Speed ref ramp input
23.02 Speed ref ramp output
24.01 Used speed reference
26.02 Torque reference used
28.02 Frequency ref ramp output
40.01 Process PID output actual
Source selection (see
Terms and abbreviations
Digital
output.
t
On
is set to
Digital
output. See
delay.
is set to
Frequency
is set to
Frequency
output.
(page 139).
(page 139).
(page 200).
(page 200).
(page 204).
(page 209).
(page 213).
(page 261).
on page 136). -
Parameters 171
Def/FbEq16
15.22
0.0 s
1
0
1
0
Time
t
Off
10 = 1 s
0.0 s
10 = 1 s
-
output.
1 = 1 Hz
Not selected
0
1
3
4
6
7
8
10
11
12
13
14
16

Hide quick links: