274 Parameters
No.
Name/Value
43.06
Brake chopper
enable
Disabled
Enabled with
thermal model
Enabled without
thermal model
43.07
Brake chopper
runtime enable
Off
On
Other [bit]
43.08
Brake resistor
thermal tc
0...10000 s
43.09
Brake resistor
Pmax cont
0.00...
10000.00 kW
43.10
Brake resistance
0.0...1000.0 ohm
43.11
Brake resistor fault
limit
0...150%
43.12
Brake resistor
warning limit
0...150%
Description
Enables brake chopper control.
Note: Before enabling brake chopper control, ensure that
• a brake resistor is connected
• overvoltage control is switched off (parameter
Overvoltage
control)
• the supply voltage range (parameter
has been selected correctly.
Brake chopper control disabled.
Brake chopper control enabled with resistor overload
protection.
Brake chopper control enabled without resistor overload
protection. This setting can be used, for example, if the
resistor is equipped with a thermal circuit breaker that is wired
to stop the drive if the resistor overheats.
Selects the source for quick brake chopper on/off control.
0 = Brake chopper IGBT pulses are cut off
1 = Normal brake chopper IGBT modulation.
This parameter can be used to program the chopper control
to function only when the supply is missing from a drive with a
regenerative supply unit.
0.
1.
Source selection (see
Terms and abbreviations
Defines the thermal time constant of the brake resistor for
overload protection.
Brake resistor thermal time constant.
Defines the maximum continuous braking power of the
resistor (in kW) which will raise the resistor temperature to the
maximum allowed value. The value is used in the overload
protection.
Maximum continuous braking power.
Defines the resistance value of the brake resistor. The value
is used for brake chopper protection.
Brake resistor resistance value.
Selects the fault limit for the brake resistor temperature
protection function. When the limit is exceeded, the drive trips
on fault
7183 BR excess
The value is given in percent of the temperature the resistor
reaches when loaded with the power defined by parameter
43.09 Brake resistor Pmax cont.
Brake resistor temperature fault limit.
Selects the warning limit for the brake resistor temperature
protection function. When the limit is exceeded, the drive
generates a
A793 BR excess temperature
The value is given in percent of the temperature the resistor
reaches when loaded with the power defined by parameter
43.09 Brake resistor Pmax cont.
Brake resistor temperature warning limit.
95.01 Supply
on page 136). -
temperature.
warning.
Def/FbEq16
Disabled
30.30
voltage)
0
1
2
On
0
1
0 s
1 = 1 s
0.00 kW
1 = 1 kW
0.0 ohm
1 = 1 ohm
105%
1 = 1%
95%
1 = 1%