Suzuki Ignis Service Manual page 2880

Rg413
Table of Contents

Advertisement

3
1
3
2
3
1
2) Connect battery to condenser cooling fan motor terminal "a"
and "b" as shown in figure, then check that the condenser
cooling fan motor operates smoothly.
Reference:
Condenser cooling fan specified current at 12 V
8 A maximum.
3) Check condenser cooling fan blade for damage. If any mal-
function is found replace condenser cooling fan.
Condenser Cooling Fan Assembly Removal
and Installation
REMOVAL
1) Remove condenser assembly referring to "Condenser
Assembly Removal and Installation" in this section.
2) Remove condenser outlet pipe mounting bolts (1) and con-
denser outlet pipe (2).
3) Remove condenser cooling fan assembly mounting bolts (3).
4) Remove condenser cooling fan assembly from condenser.
INSTALLATION
Reverse removal procedure to install condenser cooling fan
motor nothing the following instructions.
• Replenish specified amount of compressor oil to compressor
suction side by referring to "Replenishing compressor oil"
under "Operation Procedure for Refrigerant Charge" in this
section.
• Evacuate and charge refrigerant by referring to "Evacuation
of A/C system" and "Charge" under "Operation Procedure for
Refrigerant Charge" in this section.
AIR CONDITIONING (OPTIONAL) 1B-29