5E-16 ANTILOCK BRAKE SYSTEM (ABS)
Table – C ABS Warning Lamp Circuit Check – The Lamp Flashes Continu-
ously While Ignition Switch is ON
2
[A]: ABS hydraulic unit/control module connector E43
1. Battery
2. Main fuse
INSPECTION
Step
1
1) Check for proper connection to ABS control
module at ABS hydraulic unit/control mod-
ule connector.
Is it in good condition?
3
4
WHT/BLU
BLK/YEL
1
RED/BLU
3. Ignition switch
4. Circuit fuse
5. Combination meter
Action
GRN/ORN
E43-20
5
6
8
7
E43-4
E43-7
6. "ABS" warning lamp
7. Lamp driver module
8. ABS hydraulic unit/control module assembly
Substitute a known-good
ABS hydraulic unit/con-
trol module assembly and
recheck.
[A]
E43-4
E43-7
E43-20
Yes
"E43-7" terminal shorted
to ground.
No