Suzuki Ignis Service Manual page 2556

Rg413
Table of Contents

Advertisement

1
11) Connect glow plug connectors (1).
12) Install inter cooler inlet hose referring to "Inter Cooler
Removal and Installation" in this section.
13) Install air cleaner outlet hose (1) to turbocharger and then
tighten its clamp to specified torque.
Tightening torque
Air cleaner outlet hose clamp
(a): 3.1 N·m (0.31 kg-m, 2.5 lb-ft)
14) Install air cleaner assembly with MAF sensor assembly,
referring to "Air Cleaner Assembly Removal and Installation"
in this section.
15) Connect negative (–) cable at battery.
16) Check to make sure that there is no oil leakage and exhaust
gas leakage at each connection.
Turbocharger Inspection
Rotate turbine shaft (1) by hand and verify that it turns smoothly
without any abnormal noise and excessive runout.
If a malfunction is found, replace the turbocharger.
ENGINE MECHANICAL (Z13DT ENGINE) 6A3-15