CHANNEL
DESCRIPTION
COMMAND SYNTAX
QUERY SYNTAX
RESPONSE FORMAT
EXAMPLE
Digital Oscilloscope Series
BANDWIDTH_LIMIT | BWL
BANDWIDTH_LIMIT enables or disables the
bandwidth-limiting
bandwidth filters are on, it will limit the
bandwidth to reduce display noise. When you
turn Bandwidth Limit ON, the Bandwidth Limit
value is set to 20 MHz. It also filters the signal to
reduce noise and other unwanted high frequency
components.
The
BANDWIDTH_LIMIT?
whether the bandwidth filters are on.
BANDWIDTH_LIMIT<channel>,<mode>
[,<channel>,<mode>[,<channel>,<mode>[,
<channel>,<mode>]]]
<channel>:={C1,C2,C3,C4}
<mode>:={ON,OFF}
BANDWIDTH_LIMIT?
BANDWIDTH_LIMIT
[,<channel>,<mode>[,<channel>,<mode>[,
<channel>,<mode>]]]
• The following command turns on the
bandwidth filter for all channels.
Command message:
BWL C1,ON,C2,ON,C3,ON,C4,ON
• The following command turns the bandwidth
filter on for Channel 1 only.
Command message:
BWL C1,ON
Command
low-pass
filter.
query
<channel>,<mode>
/Query