  • Page 1 T3CP100-2 Current Probe Manual 100 Amp, 2 MHz Current Probe...
  • Page 2 This page is intentionally blank.
  • Page 3: Table Of Contents

    Warranty ......................14 © 2021 Teledyne LeCroy, Inc. All rights reserved. Teledyne Test Tools is a trademark of Teledyne LeCroy, Inc. Other product or brand names are trademarks or requested trademarks of their respective holders. Information in this publication supersedes all earlier versions. Specifications are subject to change without notice.
  • Page 4: General Safety Summary

    Safety Instructions Follow these instructions to keep the probe operating in a correct and safe condition. Observe generally accepted safety procedures in addition to the precautions specified here. The overall safety of any system incorporating this product is the responsibility of the assembler of the system. Symbols These symbols appear on the probe body or in documentation to alert you to important safety considerations.
  • Page 5 Never install or remove the probe on bare conductors which are energized. The transformer core and shield are grounded but not insulated and may contact the conductor when the locking lever is open. Be careful not to damage the insulation surface when making measurements. Before clamping to the conductor being measured, check that the insulation on the conductor is undamaged, and take care not to damage the insulation when clamping the conductor.
  • Page 6: Product Overview

    DC/AC 100 A Peak, 70 A rms, 2 MHz Bandwidth Teledyne Test Tools new T3CP100-2 current probe is a 2MHz bandwidth active AC/DC coupled probe, featuring 2 ranges of 100 A Peak, 70 A rms / 10A Peak, 7 A rms, fast and accurate waveform capture, risetime of <...
  • Page 7: Product Description

    When the voltage of the battery is 6.5V or lower the low battery indicator will be lit red indicating that the battery should be changed or external power applied to the probe. External DC Power Socket This is the point where the external power supply (supplied) is connected to the T3CP100-2 current probe. High / Low Range Indicators During use of the probe one of the high / low indicators will always be lit indicating the current measurement range selected.
  • Page 8 DVM / DMM then a BNC to banana plug cable may be required (not supplied), see your DVM / DMM manual. 1m BNC to BNC Output Cable Power Supply The supplied wall socket power supply (not illustrated) can be used to power the T3CP100-2 current probe in place of batteries if required. Page 5...
  • Page 9: Making Measurements

    • Set the oscilloscope’s input coupling to DC and channel attenuation ratio to 10:1 or 100:1 for correct scaling depending on the T3CP100-2 range being used. For the L range set the oscilloscope attenuation ratio to 10:1, for the H range set the oscilloscope attenuation ratio to 100:1.
  • Page 10: Accessories

    • Before using the probe for the first time, verify that it operates normally to ensure that no damage has occurred during storage or shipping. If you find any damage, contact your dealer or a Teledyne LeCroy representative. • This device is not designed to be water or dust proof. To avoid damage, do not use it in a wet or dusty environment.
  • Page 11 T3CP100-2 Specifications (continued) Low Range High Range Maximum Insulated Wire Voltage CAT II 600V, CAT III 300V Typical Battery Life 9V Alkaline: 15 Hours Low Power Indication At <6.5V the battery indicator will turn red When the measurement current exceeds the probe range the buzzer...
  • Page 12 Figure 1: Bandwidth Figure 2: Maximum Current Versus Frequency Figure 3: Typical DC Linearity (High Range) Page 9...
  • Page 13 Mechanical And Environmental Characteristics Probe Characteristic Current Clamp Dimensions 100mm x 20mm x 60mm Current Clamp Control Unit Dimensions 137mm x 33mm x 35mm Operating Altitude 0 - 2000 meters Maximum Measurement Conductor Diameter 12mm Current Clamp To Control Unit Cable Length 1 meter Output BNC to BNC Cable Length 1 meter...
  • Page 14: Certifications

    Certifications Teledyne LeCroy certifies compliance to the following standards as of the date of publication. As standards evolve, these may no longer be current. See the Declaration of Conformity shipped with your product for current certifications. EMC Compliance EC Declaration of Conformity - EMC The current probes meet the intent of EC Directive 2014/30/EU for Electromagnetic Compatibility.
  • Page 15: Safety Compliance

    EUROPEAN CONTACT:* Teledyne GmbH – LeCroy Division Im Breitspiel 11c D-69126 Heidelberg Germany Tel: (49) 6221 82700 Australia & New Zealand Declaration of Conformity - EMC The probe complies with the EMC provision of the Radio Communications Act per the following...
  • Page 16: Rohs

    EC DECLARATION OF CONFORMITY - RoHS Unless otherwise specified, all the materials and processes are compliant with RoHS Directive 2011/65/EU in its entirety, inclusive of any further amendments or modifications of said Directive. CHINA RoHS 2 Unless otherwise specified, all the materials and processes are compliant with the latest requirements of China RoHS 2.
  • Page 17: Warranty

    Spare parts, replacement parts and repairs are warranted for 90 days. In exercising its warranty, Teledyne LeCroy, at its option, will either repair or replace any assembly returned within its warranty period to the Customer Service Department or an authorized service center.
  • Page 18 This page is intentionally blank.
  • Page 19 This page is intentionally blank.
  • Page 20 © 2020 Teledyne Test Tools is a brand and trademark of Teledyne LeCroyInc. All rights reserved.Specifications,prices,availability and deliverysubject to change without notice. Product brand or brand names are trademarks or requested trademarks of their respective holders. T3 stands for Teledyne Test Tools.