TV COMMAND SYNTAX
Digital Oscilloscope Series
TRSE GLIT,SR,C2,HT,P2,HV,5nS,HV2,1uS
• When you want to set trigger type to Dropout,
trigger source to Channel 4, overtime value to
2.8 mS , the following comes true.
Command message:
TRSE DROP,SR,C4,HT,TI,HV,2.8mS
TRIG_SELECT
<trig_type>,SR,<source>,STAN,<standard>,S
YNC,<sync_type>[,LINE,<line>[,FLD,<field
>]]
Parameter description
STAN
Standard
FLD
field
CUST
Custom
<trig_type>:= {TV}
<source>:={C1,C2,C3,C4}
<standard>:={NTSC,PAL,720P/50,720P/60,1
080P/50,1080P/60,1080I/50,1080I/60 , CUST}
<line>:=allows triggering on a specific line of
video. The line number limits vary with the
standard and mode, as shown in the following
table.
TV Trigger Line Number Limits
stand
Mode
ard
Line
NTSC
PAL
720P/
1
to
50
750
720P/
1
to
60
750
1080P
1-
/50
1125
1080P
1-
/60
1125
Field
Field
1
2
1~26
1 to 262
3
1
to
1 to 312
313