Teledyne T3DSO1000 Programming Manual page 121

Digital oscilloscopes
Hide thumbs Also See for T3DSO1000:
Table of Contents

Advertisement

PASS/FAIL
DESCRIPTION
COMMAND SYNTAX
QUERY SYNTAX
RESPONSE FORMAT
EXAMPLE
RELATED COMMANDS
Digital Oscilloscope Series
The PF_SET command sets the tolerance in the
X/Y direction around the selected waveform
defined by PFSC for the Pass/Fail feature. The
value of the tolerance will be added and
subtracted to horizontal/Vertical values of the
waveform to determine the boundaries of the
mask.
The PF_ SET? query returns the current setting
of the ΔX tolerance and ΔY tolerance for
Pass/Fail.
PF_ SET XMASK,<div>,YMASK,<div>
<div>:= 0.04 to 4.0.
Note:
Step value is 0.04.
PF_ SET?
PF_ SET XMASK,<div>,YMASK,<div>
The following command sets the X mask to 0.4
and the Y mask to 0.52.
Command message:
PFST XMASK,0.4,YMASK,0.52
PFSC
PF_SET | PFST
Command /Query
121

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T3dso2000

Table of Contents