PASS/FAIL
DESCRIPTION
COMMAND SYNTAX
QUERY SYNTAX
RESPONSE FORMAT
EXAMPLE
Note:
The table below shows the availability of command in each oscilloscope series.
Model
T3DSO2000
T3DSO1000
Digital Oscilloscope Series
The PF_BUFFER command sets the output
mode when the test fails. This is the same as
pressing the "Output" button on the menu of
PASS/FAIL on the front panel.
The PF_BUFFER? query returns the current
output mode of the pass/fail.
PF_BUFFER <state>
<state>:= {ON,OFF}
• ON — The statistical result is displayed when
the failed waveform is detected, and the buzzer
alarm. (not related to the state of the sound
switch)
• OFF — The statistical result is displayed
when the failed waveform is detected, but the
buzzer does not alarm.
PF_BUFFER?
PF_BUFFER <state>
When the PASS/FAIL function is on, the
following command sets "output" to "ON".
Command message:
PFBF ON
Valid?
no
yes
PF_BUFFER | PFBF
Command/Query