6 How to Use the Software Tool
6-2

Setting of K6CM Devices

The setting of the K6CM device can be set by either of the following two methods:
• How to set in the start navigation of project creation
• How to set on the device setting screen after project creation
6-2-1

Settings for Each Monitor Type of K6CM devices

The setting values by monitor type are shown in a list.
Vibration and Temperature Type K6CM-VB
Setting parameter name
Display value type
Trigger mode
Trigger type
* Setting is not required when
the trigger mode is "Always".
Trigger level
* Setting is not required when
the trigger mode is "Always"
or "External trigger".
Monitoring time
* Setting is not required when
the trigger mode is "Always"
or the trigger type is "Level".
Alarm latch
Use Running Time
Moving Average times
Temperature unit
Acceleration alarm threshold
(Warning)
Acceleration alarm threshold
(Critical)
Velocity alarm threshold
(Warning)
Velocity alarm threshold
(Critical)
Motor temperature alarm
threshold (Warning)
6 - 22
Setting range
0: PV, 1: MIN, 2: MAX
0: Always, 1: External trigger,
2: Internal trigger
0: Rising, 1: Falling edge, 2:
Level
0.00 to 99.99
0.1 to 600.0
0: Disable, 1: Enable
0: OFF, 1: ON
0: OFF, 1: 2 times, 2: 4 times,
3: 8 times, 4: 16 times, 5: 32
times
0: °C, 1: °F
0.00 to 99.99
0.00 to 99.99
0.00 to 99.99
0.00 to 99.99
0 to 9999
K6CM Motor Condition Monitoring Device User's Manual (N219)
Description
Set which measured value is
displayed in the K6CM
device.
Set the measurement mode.
For external trigger or internal
trigger, set the starting condi-
tion of the trigger measure-
ment.
For internal trigger, set the
measurement value to start
trigger measurement.
Set the time to continue the
measurement when the trig-
ger mode is set to "External
trigger" or "Internal trigger"
with the trigger type "Rising"
or "Falling edge ".
Set the latch function when an
alarm is detected
Set the function to detect the
life of the K6CM device?
The averaging process is per-
formed on the past n times of
measured values.
Note n is the moving average
number on the shown left col-
umn.
Sets the temperature unit.
Set a threshold value for out-
putting individual alarm
(Warning) of the acceleration.
Set a threshold value for out-
putting individual alarm (Criti-
cal) of the acceleration.
Set a threshold value for out-
putting individual alarm
(Warning) of the velocity.
Set a threshold value for out-
putting individual alarm (Criti-
cal) of the velocity.
Set a threshold value for out-
putting individual alarm
(Warning) of the motor tem-
perature.
Default
0: PV
0: Always
0: Rising
0.00
0.1
1: Enable
0: OFF
0: OFF
0: °C
0.50
1.00
40.00
45.00
80