Omron K6CM User Manual page 153

Motor condition, monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

Setting parameter name
Motor temperature alarm
threshold (Critical)
Temperature Gap alarm
threshold (Warning)
Temperature Gap alarm
threshold (Critical)
Transistor output type
Insulation Resistance Type K6CM-IS
Setting parameter name
Display value type
Trigger mode
Trigger type
* Setting is not required when
the trigger mode is "Always".
Trigger level
* Setting is not required when
the trigger mode is "Always "
or "External trigger".
Monitoring time
*Setting is not required when
the trigger mode is "Always"
or the trigger type is "Level".
Alarm latch
Use Running Time
Moving Average times
Applicable circuit
Using inverter
Inverter special measurement 0: OFF, 1: ON
Insulation resistance alarm
threshold (Warning)
K6CM Motor Condition Monitoring Device User's Manual (N219)
Setting range
0 to 9999
0 to 9999
0 to 9999
0: Normally closed,
1: Normally open
Setting range
0: PV, 1: MIN, 2: MAX
0: Always, 1: External trigger,
2: Internal trigger
0: Rising, 1: Falling edge, 2:
Level
0.00 to 99.99
0.1 to 600.0
0: Disable, 1: Enable
0: OFF, 1: ON
0: OFF, 1: 2 times, 2: 4 times,
3: 8 times, 4: 16 times, 5: 32
times
0: Three-phase three-wire
S-phase ground
1: Three-phase four-wire
N-phase grounded load side
delta connection
0: OFF, 1: ON
0.000 to 9.999
6 How to Use the Software Tool
Description
Set a threshold value for out-
putting individual alarm (Criti-
cal) of the motor temperature.
Set a threshold value for out-
putting individual alarm
t
(Warning) of the
emperature
gap.
Set a threshold value for out-
putting individual alarm (Criti-
cal) of the temperature gap.
Select transistor output type.
Description
Set which measured value is
displayed in the K6CM
device.
Set the measurement mode.
For external trigger or internal
trigger, set the starting condi-
tion of the trigger measure-
ment.
For internal trigger, set the
measurement value to start
trigger measurement.
Set the time to continue the
measurement when the trig-
ger mode is set to "External
trigger" or "Internal trigger"
with the trigger type "Rising"
or "Falling edge ".
Set the latch function when
an alarm is detected
Set the function to detect the
life of the K6CM device?
The averaging process is per-
formed on the past n times of
measured values.
Note n is the moving average
number on the shown left col-
umn.
Set the applicable circuit
according to the distribution
method of the equipment to
be monitored.
Set according to the pres-
ence or absence of the
inverter of the equipment to
be monitored.
Set according to the inverter
frequency setting of the
equipment to be monitored.
Set a threshold value for out-
putting individual alarm
(Warning) of the insulation
resistance.
Default
80
80
80
0
Default
0: PV
0: Always
0: Rising
0.00
0.1
1: Enable
0: OFF
0: OFF
0: Three-phase three-wire
S-phase ground
0: OFF
0: OFF
0.800
6 - 23
6