Omron K6CM User Manual page 243

Motor condition, monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

When the installation is completed, the device is added to the hardware list.
4
Registering devices
(1) Device registration to the network configuration
Register the EtherNet/IP devices which participate in the tag data links in the Network Con-
figuration Window.
From the hardware list, you can register a PLC as an originator device and K6CM devices,
by dragging and dropping each device at a time, or by selecting and double-clicking it.
As an example, register a CJ1W-EIP21 (Rev 3) in the "Communications Adapter" category
as an originator device and register a K6CM-CIM as a target device.
Note Select the same model as the device you use and register it.
The device names and major CIP revisions (Rev □) are displayed in the hardware list.
The device name and the major CIP revision of the CS/CJ-series CPU Unit are as follows.
Device name in hard-
CJ2B-EIP21
CJ2M-EIP21
CJ1W-EIP21
K6CM Motor Condition Monitoring Device User's Manual (N219)
Drug
Unit version
ware list
Unit version.2.0 and 2.1
Unit version.3.0
Unit version.2.0 and 2.1
Unit version.1.0
Unit version.2.0 and 2.1
Unit version.3.0
CIP revision
Major revi-
Revision name in hardware
sion
2
Rev2
3
Rev3
2
None
1
Rev1
2
Rev2
3
Rev3
Appendices
A
list
A - 27