Measurement System; Sampling Of Measured Values - Omron K6CM User Manual

Motor condition, monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

3-2

Measurement System

3-2-1

Sampling of measured values

The input from the sensor is given to the K6CM device as a measured value in every sampling period.
The sampling period depends on the measured target as follows.
Monitor type
Vibration and tem-
perature type
Insulation resis-
tance type
Comprehensive cur-
rent diagnosis type
Also, until the next sampling is completed, the present measured value is held as the current value.
When the power is turned OFF, the held measurement value is reset.
Sampling period
Measured value 1 is the current value
until sampling of measured value 2 is
completed.
Note The sampling of the measured value is performed internally even in the case of the unmeasured state
before the trigger start.
K6CM Motor Condition Monitoring Device User's Manual (N219)
Measurement target
Acceleration
50 ms
Velocity
0.5 s
Temperature
0.5 s
Insulation resistance
10 s (Normal mode)
60 s (Inverter special measurement
mode)
Degradation level
5 s
Current
5 s
Measured value 2
Measured value 1
Measured value 2 is the current value
when sampling of measured value 2 is
completed.
3 Measuring and Monitoring Mechanism