Data name
Sets the trigger level when the trigger mode is "internal trigger".
Set value: Set in each measurement range.
Note : Unit and decimal point position follow measured val-
Trigger level
For each K6CM, set the trigger level for the following monitor-
ing category.
• Vibration & temperature type: Acceleration
• Insulation resistance type: Insulation resistance
• Comprehensive current diagnosis type: current
In the case of an internal trigger or an external trigger, set the
time to continue monitoring when the trigger type rises or falls.
Monitoring
time
Setting value: 0.1 to 600.0 seconds.
It is common in case of internal trigger and external trigger.
Sets enable /disable of alarm latch function.
Alarm latch
0: Disable (no latch)
1: Enable (with latch)
Sets the usage or nonuse of K6CM remaining capacity func-
tion.
Use Run-
ning Time
0: OFF (not used)
1: ON (use)
Every time the measured value is sampled, the data of the past
n times including the sampling data of that time is averaged.
0: OFF
Moving
1: 2 times
average
2: 4 times
times
3: 8 times
4: 16 times
5: 32 times
Select transistor output type.
Transistor
0: Normally closed
output type
1: Normally open
Vibration & temperature Type (K6CM-VBM)
Data name
Sets the temperature unit.
Tempera-
0: °C
ture unit
1: °F
Note If you change from "° C" to "° F", a temperature alarm may be generated depending on the setting of the
alarm setpoint. When you have changed the setting of the temperature unit, also change the alarm set-
points of the motor temperature and temperature gap to the set value according to the temperature unit.

K6CM Motor Condition Monitoring Device User's Manual (N219)

Description
ues.
Description
Appendices
Writing method (Yes: supported, No: sup-
ported)
CIP mes-
Software
sage com-
Tag data link
tool
munications
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Writing method (Yes: supported, No: sup-
ported)
CIP mes-
Software
sage com-
Tag data link
tool
munications
Yes
Yes
No
A
No
No
No
No
No
No