4 Introduction of the Software Tool
Details of the file to be created
Precautions for Correct Use
Do not use project files which are created with the software tool with the new version if you use
the software tool with the older version. The software tool may not operate correctly.
Exten-
File type
sion
Project file
.k6cm
Binary file including
• Device configuration information including motor group
• Device setting value
• Event log information
• Related log file information
Parameter data
.k6pa
Binary file of parameter values for each device
file
Log file
.csv
Automatic log file of monitored information.
It is used for graph display inside the tool.
It is CSV format, so it can be used by other applications.
Note : Depending on the amount (size) of acquired data, it may be divided
File name: Project name _IIIIII_TT_YYYYMMDD_NNNN.csv
The contents of the file are as follows. One record consists of the following
two lines.
Line 1: [Device name], [Monitor type name]
From the second line: [Date and time], [Current value], [Threshold (Warn-
ing)], [Threshold (Critical)], [K6CM status], [Measurement status]
• Device name:
• Monitor type name?
• Date and time:
• Current value, threshold (Warning), threshold (Critical):
• K6CM status, measurement status:
4 - 4
Description
and saved.
IIIIII: Device ID (000000 to 999999)
TT: Monitor type (00 to 06)
00: acceleration, 01: velocity, 02: motor temperature,
03: temperature gap, 04: insulation resistance, 05 degradation level,
06: current
YYYY: Year
MM: Month (01 - 12)
DD: days (01 to 31)
NNNN: Serial number (the above-mentioned device ID, monitoring cate-
gory, number for identifying the same date year / month / date)
Any one of "K6CM_VB", "K6CM_IS", "K6CM_CI"
Any one of "acceleration", "velocity", "motor temperature", "temperature
gap", "insulation resistance", "current", "degree of degradation"
A character string representing the date and time on the computer system
when monitoring
Monitoring form Character string expressing the current value, threshold
value (Warning), threshold value (Critical) of K6CM device in decimal
number with decimal point
Monitoring form Character string in hexadecimal representation of each of
the 16 bits of the K6CM status and measurement status of the K6CM
device (Refer to the next page for details on the CSV file content and sta-
tus)
K6CM Motor Condition Monitoring Device User's Manual (N219)
Save position by default
C: \ OMRON \ Motor condi-
tion monitoring Tool
Same as above
Directly under the folder of
the project file name | folder
of the motor name