*2. Measurement status (common form of measured values)
The measurement status is handled as 2-byte data consisting of bit data in the table.
Example: The individual alarm result (Warning) is "ON".
The 12th bit is "1", so it is "0001 0000 0000 0000" in binary notation and "1000" in hexadecimal notation.
In the log file (CSV) of the Motor condition monitoring tool, the K6CM status is in hexadecimal notation.
Bit position
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Precautions for Correct Use
If there is no trigger, read the data when "Present value not measured" bit (bit 00) of the mea-
surement status is 0.
There is a possibility that the value before measurement and monitoring (i.e., 0) is being read.
K6CM Motor Condition Monitoring Device User's Manual (N219)
8 Monitoring and Setting Using the EtherNet/IP Devices
Status
Present value unmeasured state
Present value input error
Reserved.
Reserved.
Maximum value unmeasured state
Maximum value input error
Reserved.
Reserved.
Minimum value unmeasured state
Minimum value input error
Reserved.
Reserved.
Individual alarm result (Warning)
Individual alarm result (Critical)
Reserved.
Reserved.
Bit contents
0
Measured status
Unmeasured status
Not occurred
Occurrence
Measured status
Unmeasured status
Not occurred
Occurrence
Measured status
Unmeasured status
Not occurred
Occurrence
OFF
ON
OFF
ON