Trigger Mode - Omron K6CM User Manual

Motor condition, monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

3-2-3

Trigger Mode

Trigger is a function of updating and monitoring the measured values when certain conditions are met.
To observe the aging of the motor, it is necessary to set the installation state, load, and rotation speed
of the motor during measurement to the same condition, and to measure the motor rotating at a con-
stant speed avoiding the state where the motor is stopped or accelerating or decelerating. Depending
on the application, select the trigger mode from Always (while power is ON), External Trigger, or Inter-
nal Trigger. The operation of each trigger mode is shown in the table below.
Start condition
Trigger
mode
and monitoring
All times after
Always (while
turning ON the
power of the
power is ON)
K6CM device
Depends on exter-
nal conditions
External trig-
ger
Depends on the
relationship
between the mea-
surement value
and the set value
(trigger level)
Internal trig-
ger
When selecting external trigger or internal trigger mode, set measurement start and end conditions by
selecting trigger type.
K6CM Motor Condition Monitoring Device User's Manual (N219)
of measuring
Rising edge
Measuring time
ON
Measurement and moni t ori n g
OFF
• Start condi-
When the external trigger
tion
input changes from OFF to
ON
• End condi-
After the measurement
tion
time has elapsed
Measuring time
Set
value
Measurement and moni t ori n g
• Start condi-
When the measurement
tion
value exceeds the set
value (trigger level)
• End condi-
tion
After the measurement
time has elapsed
3 Measuring and Monitoring Mechanism
Trigger type
Falling edge
Always measuring
Measuring time
ON
Measurement and moni t ori n g
OFF
When the external trigger
input changes from ON to
OFF
After the measurement
time has elapsed
Measuring time
Set
value
Measurement and moni t ori n g
When the measurement
value falls below the set
value (trigger level)
After the measurement
time has elapsed
Level
ON
Measurement and moni t ori n g
OFF
While the external input is in
the ON state
Set
value
Measurement and moni t ori n g
While the measurement
value exceeds the set value
(trigger level)
Note : For the insulation
resistance, this is
while present value
falls below the set
value.
3 - 5