Omron K6CM User Manual page 165

Motor condition, monitoring device
Hide thumbs Also See for K6CM:
Table of Contents

Advertisement

Monitor with the Transistor Outputs
When monitoring with the transistor outputs, the following monitoring is available.
Transistor
Transistor
Output 1
Output 2
*1
OFF
OFF
*1
*1
ON
ON
*1
*1
OFF
ON
*1
OFF
OFF
OFF
OFF
*1. This is the output result when "Transistor output type" is set to "Normally closed". By default, it is set to "Nor-
mally Closed". By setting it to "Normally Open" with the software tool or EtherNet/IP, ON/OFF can be
reversed.
*2. When the trigger mode is "Always", "MON" lights up.
Status display:
"MON": Measurement
and monitoring
in progress
"ERR": Self-diagnosis
error occurrence
K6CM Motor Condition Monitoring Device User's Manual (N219)
7 Motor Monitoring with the K6CM Devices and the Software Tool
Transistor
Status
Output 3
display
ON
*1
*2
Not lit.
ON
"MON"
ON
ON
*1
OFF
"ERR"
Status
Measuring and mon-
In the case of a trigger, measuring and monitor-
itoring Not yet
ing is not started yet after the power is turned
ON.
Comprehensive
All measured values are
alarm: normal
in normal condition.
Comprehensive
There is no "critical" in
alarm: Warning
the measurement value,
There is "warning" even if
at least one state.
Comprehensive
There is "critical" in even
alarm: Critical
one measurement value.
When the self-diag-
Self diagnostic error is occurring.
nosis error occurs
Terminal
Meaning
In the case that the transister type is
Warning output
Normally closed,
Transistor
of comprehen-
ON: Comprehensive alarm is normal
Output 1 (+)
sive alarm.
OFF: Comprehensive alarm is warning or
Transistor output
critical
type can be set
In the case that the transister type is
to Normally
Normally open,
Closed or
Transistor
ON: Comprehensive alarm is warning or
Normally Open.
Output 1 (-)
critical
OFF: Comprehensive alarm is normal (* 3)
In the case that the transister type is
Critical output of
Normally closed,
Transistor
comprehensive
ON: Comprehensive alarm is normal
Output 2 (+)
alarm.
OFF: Comprehensive alarm is warning or
critical
Transistor output
type can be set
In the case that the transister type is
to Normally
Normally open,
Transistor
Closed or
ON: Comprehensive alarm is warning or
Output 2 (-)
Normally Open.
critical
OFF: Comprehensive alarm is normal (* 3)
Self-diagnosis
Transistor
error output.
In the following cases, ON
Output 3 (+)
Transistor output
When self-diagnosis error does not occur
type is Normally
In the following cases, OFF
Transistor
Closed, and can
When self-diagnosis error occurs
Output 3 (-)
not be changed
*3.In either of the following cases, the transistor output
turns OFF regardless of the transistor output type.
• Measurement and monitoring is not performed (only
when using the trigger function)
• Self-diagnosis error occurrence
In addition, transistor output state (ON/OFF) is held at
the end of measurement and monitoring (only when
using the trigger function)
Meaning
At the end of mea-
suring and monitor-
ing, the state of
transistor outputs 1
and 2 are retained
(only when using
the trigger func-
tion). "MON" will go
out at this time.
Operation
7 - 7
7

Advertisement

Table of Contents
loading

Table of Contents