Initial Setting of K6CM Devices

This section describes how to initialize the K6CM using the Motor condition monitoring tool.
5-4-1

Overview

The setting of the K6CM device can be set by either of the following two methods:
• How to set in the start navigation of project creation
• How to set on the device setting screen after project creation
5-4-2

Motor condition monitoring Tool Connection Method

There are two ways to connect the Motor condition monitoring Tool to the K6CM.
• Automatic connection (direct one-to-one connection)
• Fixed IP Connection (connection via hub)
Automatic connection (direct one-to-one connection)
Directly connect the computer and each K6CM device via the Ethernet cable without going through the
hub.
In the case of direct connection, there are the following merits:
• Can be connected without specifying IP address of K6CM device.
Either straight type or cross type Ethernet cable is available.
Note If the IP address setting method of the K6CM device is set to BOOTP, auto connection can not be made
until connecting to the BOOTP server.
Create the project
IP address setting
K6CM Motor Condition Monitoring Device User's Manual (N219)
5 Setting with the Motor condition monitoring Tool
Parameter setting (as necessary)
100 to 240 VAC or
24 V power supply (by type)
EtherNet/IP port
Motor Condition
Monitoring Tool
Ethernet cable
(Straight or cross)
Motor condition monitoring
equipment
K6CM device
5 - 35
5