2 Nomenclature and Functions
Name
Types of measurement
When the K6CM device is being measured
such as present value,
and monitored, LCD character shown in the
minimum value, and max-
right column indicates whether the measure-
imum value
ment value displayed on the LCD is the pres-
ent value, the minimum value, or the
maximum value.
Note : Switching display of current value,
Numeric LCD display
• When measuring and monitoring is started,
the measurement value is displayed.
Switching display of the monitoring cate-
gory on the right can be performed by
[DISP] key.
• With trigger (external trigger or internal trig-
ger), "- - - -" is displayed if measuring and
monitoring is not started yet. When the
measuring and monitoring is completed,
the measurement value just before the end
is retained and displayed.
Note : When the vibration & temperature
For details, refer to Transition of Numeric LCD
Display on page 2-7.
Status display
K6CM device status is one of measuring and
monitoring in progress, self-diagnosis error,
operation summation status, with the LCD
character on the right.
Note : Running Time is a function to inform
Product and network sta-
Indicates the product status or network status
tus indications
by LEDs.
External trigger input
Trigger input by external input that sets the
K6CM device status during measuring and
monitoring (status display "MON").
2 - 4
minimum value, and maximum value
can be set by changing "Display
value selection" from the software
tool.(It is not switchable by front oper-
ation.)
sensor or the insulation resistance
sensor (ZCT (IRT)) is not connected,
"- - - -" is displayed and the MS
flashes. When the input range is
over, 7 segments will flash with the
maximum value of the input range.
you when to replace the K6CM
device. It is calculated from the inter-
nal temperature and the operation
time of the device.
Meaning
• "PV": present value
• "MIN": minimum value
• "MAX": maximum value
The minimum and maximum values indicate the current mini-
mum and maximum values in one measuring and monitoring
period.
The display is updated each time the minimum and maximum
values are updated. Both are retained at the end of measuring
and monitoring, but will be reset the next time the power is
turned ON again.
• Acceleration, Velocity, Motor temperature, Difference
between Motor temperature and room temperature (Vibra-
tion & temperature type)
• Insulation resistance, Leakage current (Insulation resis-
tance type)
• Degradation level, current (Comprehensive current diagno-
sis type)
• "MON": Measuring and monitoring in progress
• "ERR": Self-diagnosis error occurrence
• "AGE": operation totalization notification (recommendation
for exchange of product body)
• "MS": ModuleStatus. Displays the status of the K6CM
device. It is green when it is normal.
• "NS": Network Status. Displays the state of the communica-
tions. It lights or flashes green when it is normal.
Note : For details, refer to Product and Network Status Indi-
cations Details on page 2-6.
Measurement and monitoring can be started during the rise
from OFF → ON or the fall from ON → OFF, and measure-
ment and monitoring up to the measurement time, or mea-
surement and monitoring in the ON state can be selected.