4 AUXILIARY AND APPLIED FUNCTIONS

4.4 ROM Operation Function

4.4.1 Specifications of 7-segment LED/switches

Q172DCPU
0
0
2)
1
STOP RUN
EMI
This function is used to operate based on the data in the FLASH ROM built-in Motion
CPU module that the user programs and parameters have been stored.
No.
1)
1)
2)
SW
3)
2
3)
CAUTION
FRONT
BAT
(1) Operation mode
"Operation mode" of the Motion CPU is set by the rotary switch setting of Motion
CPU module at the power supply ON of the Multiple CPU system.
The rotary switch setting, operation mode and operation mode overview are
shown below.
(a) Rotary switch setting and operation mode
Rotary switch setting
SW1
Any setting
(Note-1): Do not set other than the above setting.
(Note-2): The programs, parameters, motion devices (#), devices of latch data and
absolute position data of SRAM built-in Motion CPU module are cleared.
Items
7-segment LED
Rotary switch 1 (SW1) • Set the operation mode (Normal mode, Installation
Rotary switch 2 (SW2)
(Note-1)
SW2
A
Any setting (Except C)
0
0
0
6
0
8
C
4 - 22
Functions
• Indicate the operation state and error information.
mode and mode operated by ROM, etc.)
• Each switch setting is 0 to F.
Operation mode
Installation mode
Mode operated by RAM
Mode operated by ROM
Ethernet IP address display mode
SRAM clear
(Note-2)

Advertisement