2.3 Turning the Power ON, Initializing the Memory, and Setting the Parameters

(1) Turning the power ON
Always check the cable connections, etc., before turning the power ON. Take special care to the
power system connection state.
After turning the power ON, confirm that the screen can be changed.
(2) Setting the basic specification parameters and initializing the memory
1) Refer to section "2.4.4 Setup Parameter" in the "Chapter 1 Screen Operations", and display
2) Refer to the Parameter Manual, and set the base specifications parameters (#1001 to #1019,
3) Set "#1060 SETUP" (normally set to "0") to "1", and execute the one-touch setup. The
4) Turn the control unit's input power OFF and ON.
This completes the initialization of the memory.
(3) Setting the parameters
1) Refer to section "2.4.4 Setup Parameter" in the "Chapter 1 Screen Operations", and display
2) Refer to the Parameter Manual, and set the parameters.
Downloaded from
ManualsNet.com
2. Startup and Adjustment Procedures
2.3 Turning the Power ON, Initializing the Memory, and Setting the Parameters
the screen for the setup parameters.
#1025 to #1043).
memory will be initialized according to the basic parameters.
the screen for the setup parameters.
CAUTION
Do not change the setup parameters without consent from the machine maker.