Downloading New Operational Code

Document No. 650-100-700, Issue 1
To download new operational code in BOOT mode into APP1 or APP2.
* Note: The Avaya P580 and P882 Multiservice switches do not have an
IP address assigned to the console ethernet port when it comes
up in BOOT mode. Therefore, a user must assign an IP address
(and default gateway) to the ethernet console port prior to
attempting the TFTP download of a new operational image.
1. Ensure the ethernet console port is connected to the network for a TFTP
transfer.
2. Enter the following command to assign an IP address to the ethernet
console port:
Boot> ip address <ip address> <ip mask>
3. Enter the following command to assign a default gateway to the ethernet
console port (if necessary):
Boot> ip default_gateway <ip address>
4. Enter the following command to download new operational code to
APP1 or APP2:
Boot> download <app1|app2> <serverIP> <filename>
5. Enter the following command to set the switch to boot from the
appropriate image stored in APP1 or APP2
Boot> feprom set <app1|app2>
6. Enter the following command to reset the switch:
Boot> reset
Boot Mode
B-3