Setting Interval wiping

When a set time has elapsed, the machine automatically
wipes the nozzle surfaces of the head to remove any ink
droplets attached to the surfaces.
In case that deflection, nozzle missing, or symptom which
ink droplets fall down occurred, set the interval between
each operation shorter.
1
Press the
Local.
2
Press
to select SETUP 1 to 4, and
press
key.
• Setup menu will be displayed.
3
Press the
4
Press
to select "Interval Wiping"
, and press the
5
Press
to set intervals.
• Set Value : 3 to 255 min, OFF
• When selecting 3~255 min, execute the feed
setting.
• When turning it ON, it feeds the media until the
media passes Color fixation device.
• When [OFF] is set, periodical wiping is not
executed.
6
Press
key.
7
Press
the setting.
• The color tone may change, depending on the
timing when periodic wiping is performed. Check
in advance that the color tone is not affected.
key in
(MENU)
(>>) twice.
key.
key several times to end

Setting Head Gap

Set the head gap (height from the media to the nozzle
plane of the heads).
1
Press the
Local.
2
Press
to select SETUP 1 to 4, and
press
key.
• Setup menu will be displayed.
3
Press the
4
Press
to select "Head Gap" and
press the
5
Press
to select the Head Gap
value, and press the
• Set value : 1.5 to 7.0mm
6
Press
key.
7
Press
the setting.
Chapter 3 Setup
key in
(MENU)
(<<).
key.
key.
key several times to end