Setting Interval Wiping; Setting Head Gap - MIMAKI TS500P-3200 Operation Manual

Hide thumbs Also See for TS500P-3200:
Table of Contents

Advertisement

Setting Interval wiping

When a set time has elapsed, the machine automatically
wipes the nozzle surfaces of the head to remove any ink
droplets attached to the surfaces.
In case that deflection, nozzle missing, or symptom which
ink droplets fall down occurred, set the interval between
each operation shorter.
1
Press the
Local.
2
Press
to select SETUP 1 to 4, and
press the
• Setup menu appears.
3
Press the
4
Press
to select "Interval Wiping"
, and press the
5
Press
to set intervals.
• Set Value : 3 to 255 min, OFF
• When [OFF] is set, periodical wiping is not
executed.
6
Press the
7
Press the
end the setting.
• The color tone may change, depending on the
timing when periodic wiping is performed. Check
in advance that the color tone is not affected.

Setting Head Gap

Set the head gap (height from the media to the nozzle
plane of the heads).
1
Press the
Local.
2
Press
to select SETUP 1 to 4, and
press the
• Setup menu appears.
3
Press the
(<<).
4
Press
to select "Head Gap" and
press the
5
Press
to set a value of the head
gap and press the
• Set value : 1.5 to 7.0mm
key in
(MENU)
key.
(>>) twice .
key.
key.
key several times to
key in
(MENU)
key.
key.
key.
6
Press the
key.
7
Press the
end the setting.
• The color tone may change, depending on the
timing when periodic wiping is performed. Check
in advance that the color tone is not affected.
Chapter 3 Setup
key several times to
3-15
3
2
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents