Clean the part of the sensor with a clean
stick.
4
Return the flushing unit to the original
position.
(1) Hold The Handle And Shift The Flushing
Unit.
(2) Fasten the clasp.
Handle

Cleaning the ink receiving sponge

1
Shift the flushing unit to the left.
• Please conduct the operation up to P.4-6
"Cleaning the Flushing BOX Sensor" step 2.
Handle
2
Remove the flushing cover, and take out
the ink receiving sponge.
(1) Remove the screws (4 locations) of flushing
cover, and remove the cover.
Sensor
clasp
clasp
Flushing cover
(2) Remove the ink receiving sponge holding,
and take out the ink receiving sponge.
3
Soak the ink receiving sponge in tap water,
and lightly rubbing wash.
• Please ask the industrial waste treatment
company for the waste liquid treatment of the
waste that washed the sponge.
4
Return the flushing unit to its original
state.
• Install the flushing cover with the screw on the
back side.
• Please make sure that ink receiving sponge, ink
sponge holder, and flushing cover are seated in
the ink receiver.
Ink receiver
Chapter 4 Maintenance
Sponge
Screw
4-7