Chapter 2 Basic Operation
Displaying the status of the color
fixation device
The color and the letter of the icon on the local TOP
screen change depending on the status of the color
fixation device.
Example 1) Stable
Local <Setup 1>
Roll <   > Leaf
CONSTANT
179° C/180° C
MENU
Example 2) OFF
Local <Setup 1>
Roll <   >Leaf
OFF
----/----
MENU
Status Table
State
NO.
Stable
CONSTANT
1
OFF
2
Waiting
3
Cooling
COOLING
4
down
Standing by
STAND-BY
5
Heating up
6
Error Event
7
• You can set the temperature when fixing the color
in FUNC2 (HEATER).
Setting range: 150 to 200
Setting unit: Increments of 1
2-32
12:00
Media Select
TEST PRINT /
REMOTE
CLEANING
12:00
Media Select
TEST PRINT /
REMOTE
CLEANING
Icon
Descriptions
The machine has
arrived at the Color
fix.temp. and is
stable.
Just after starting
OFF
up, or door OPEN.
WAITING
Heater OFF
Lowering the
temperature in the
heater.
Maintaining the
stand-by
temperature.
Raising the
HEATING
temperature in the
heater.
Error has been
ERROR
generated.

Printing Workflow

Print flow when timer function is OFF
Send print data
Printer
Local→Remote
Heater ON
Waiting to reach coloring heater
temperature
"Please wait. Under temperature
control."
Start printing
Stop printing
Heater OFF
Print flow when timer function is ON
Send print data
Printer
Local→Remote
Heater ON
Waiting to reach coloring heater
temperature
"Please wait. Under temperature
control."
Start printing
Stop printing
Timer set time elapses
Heater OFF
Color fixation device
Heater ON
Screen display: "HEATING"
Attained Color fix.temp.
Screen display: "READY"
Heater OFF
Screen display: "COOLING"
Color fixation device
Heater ON
Screen display: "HEATING"
Attained Color fix.temp.
Screen display: "READY"
Heater OFF
Screen display: "COOLING"