Setting The Color Fixation Device From The Printer - MIMAKI Tx500P-3200DS Operation Manual

Table of Contents

Advertisement

Specification
of terminal
connection
Terminal
Signal
number
name
+24V
24V output Max 500mA
1
IN+
External input plus side
2
IN-
External output minus side
3
GND
GND
4
OUT+
5
Non-voltage contact output
24 V 3A or less
OUT-
6
• Connection example
The external input sensor is NPN connected
: Short the terminal numbers 1 and 2, and connect the
sensor output 3 and GND to 4.
The external input sensor is PNP connected
: Short the terminal numbers 3 and 4, and connect 1 to
the sensor power supply and 2 to the output.
Set backlight of the touch panel
It sets whether to turn off the backlight of the touch panel
when heater is off.
1
Touch the
button on the top screen.
• The setting menu will be displayed.
2
Touch the
button.
• The backlight setting screen will be displayed.
3
Touch the [Backlight Setting] button.
• The backlight setting screen will be displayed.
block for external
input
Spec
Chapter 2 Basic Operation
4
Set the backlight.
• [Backlight off function]
[Enable] : Turn off the backlight when the
heater is off.
[Disable] : Always on.
• [OFF Timer]
[Enable] : Set the time (minutes) until the
backlight is turned off.
Setting the Color Fixation Device
from the Printer
You can turn the color fixation device on/off, as well as set
the temperature and the timer from the printer's Setup
menu.
Setting the color fixation device
1
Press the
in Local.
2
Press
to select SETUP 1 to 4, and
press the
3
Press
to select [Color fixation
device], and press the
Setup 1
Feed Comp.
DropPos.Correct
Color Fix. Device
Logical Seek
Overprint
<<
• Set the [Color fixation device] to [ON] to display a
variety of settings.
Color fixation device
Color fix.temp.
Stand-by temp.
Timer OFF
Timer ON
<<
• Color fix.temp.
Set the temperature when fixing the color.
Setting range: 150.0 to 200.0 ℃
Setting unit: Increments of 0.1 ℃
• Stand-by temp.
Set the temperature when standing by.
Setting range: OFF, 100.0 to 150.0 ℃
Setting unit: Increments of 0.1 ℃
• Timer OFF
Set the time before the heater turns off
automatically.
Setting range: OFF, 1 to 60 min
• Timer ON
Set the time before the heater turns on
automatically.
Setting range: OFF, 1 to 12H
(MENU)
key
key.
key.
1/4
>
>
ON
Host
Host
>>
180.0℃
100.0℃
30min
12H
>>
2-31
2
2
2
2