Chapter 5 Troubleshooting
Message
ERROR E01
Fixing Machine Com
SYSTEM HALT
Message
SYSTEM HALT (*)
000 :MESSAGE
Reason and corrective measure for the error of color fixation device
Message
SSR 1~8
BLOWER1
BLOWER2
TEMPERATUBE
PRINTER_EMR
HEATER_EMR
THERMOSTAT
COVER OP HI TEMP
COVER OPEN
HT TIMEOUT
5-18
Cause
Failed to communicate with the color fixa-
tion device.
• Turn off the main power to the machine and turn it on after a while.
Check the number and contact your local distributor to call for service.
("000" is the error No.)
Cause
It lights in red with the AC input error.
It lights in red with the inverter error.
It lights in red when stopped during the
blower movement order.
It lights in red with the temperature error.
When the emergency switch on the printer
side is pressed,
It turns red on when the heater emergency
switch is pressed in [MAINTE].
It lights in red when the heater emergency
switch is pressed.(Except in [MAINTE])
It lights in red with the temperature error.
It lights in red when the heater furnace is
open in the state of high temperature.
It lights in red when the heater furnace is
open.
It lights in red when the heater is left with
being turned on.
Measures
• Disconnect and then reconnect the
cables between the printer and the color
fixation device.
• If the same error message appears
again, contact your local distributor to call
for service.
Measures
Measures
• Turn off the power button to the machine
and turn it on after a while.
• If the same error message appears
again, contact your local distributor to call
for service.
• Press the [RES] key to remove the error.
• Press the [RES] key to remove the error.
• Check if the media got loose in the heater
furnace or it works correctly.
• Press down the [RES] key to cancel the
error after a while and turn the heater on.
• Release the emergency switch after
avoiding a danger and press the [RES]
key.
• Release the emergency switch after
avoiding a danger and press the [RES]
key.
• Check if the media got loose in the heater
furnace or it works correctly.
• Press down the [RES] key to cancel the
error after a while and turn the heater on.
• Accessing the heater furnace must be
done when it is cooled down.
• Press the [RES] key to remove the error.
• Close the heater furnace.
• Turn it off when not using the heater.