Operation Menu Of Color Fixation Device - MIMAKI Tx500P-3200DS Operation Manual

Table of Contents

Advertisement

Operation Menu of Color fixation Device

Status
Time
[Status]
WAITING Displayed in the waiting mode.
HEATING Displayed while the device is
heating up to the color fixation
temperature.
READY
Displayed when the color
fixation temperature has been
reached.
COOLING Displayed until the
temperature in the furnace
drops after you switch off the
heater.
HEATING : S Displayed while the device is
heating up to the standby
temperature.
STANDBY Displayed when the standby
temperature has been
reached.
ERROR
Displayed when an error
occurs.
MAINTE
Displayed when the power
supply is switched on.
[LOCAL]
Select this when turning the heater on or
off on the heater side.
[REMOTE]
Select this when turning the heater on or
off on the printer side.
[PV]
Current temperature
[SV]
Set temperature
Status
Time
[HEATER]
Switches the heater on or off in the LOCAL
control mode.
Only the OFF setting is available in the
REMOTE control mode.
[DOOR]
This button releases the door lock.
You can release the lock when the
temperature inside the furnace does not
exceed 50°C in the MAINTE
mode (when LOCAL or REMOTE is
switched off).
[LOG]
Displays a list of the operation and error
logs of the heater.
Refer to the error list for error descriptions.
[ERROR]
Opens a window with simple error
descriptions.
Status
Time
Displays the changes in the temperature
inside the furnace.
Chapter 2 Basic Operation
Status
Time
[Log window (2 lines per log)]
Line 1: Date and time of occurrence
Line 2: Event code/error code
[
/
]
Log scroll
* This function is disabled if the log window
is not selected.
[Clearing the log]
To clear the log, go to the setting menu
and select [Log Clear].
Status
Time
[SSR 1~8]
Lights up when a power controller,
heater or SSR error occurs.
* To reset the warning lamps, turn the main
power supply off.
[BLOWER1]
Lights up when an error occurs in the
inverter.
[BLOWER2]
Lights up if the blower stops when the
command for its operation is active.
[TEMPERATUBE]
Lights up when a control temperature error
occurs.
[PRINTER_EMR]
Lights up when the emergency button is
pressed on the printer side.
[HEATER_EMR]
Lights up when the emergency button is
pressed on the color fixation device side.
[THERMOSTAT]
Lights up when an error in the internal
temperature of the furnace occurs.
* This warning lamp cannot be reset until
the temperature inside the furnace drops.
[COVER OP HI TEMP]
Lights up if you open the cover when the
temperature inside the furnace is high.
[COVER OPEN]
Lights up when the cover is opened.
[HT TIMEOUT]
Lights up when the heater is left on.
[FILTER CLEANING]
Lights up when the cleaning alarm for the
filter of the heater electric components is
activated.
[FILTER REPLACE]
Lights up when the replacement alert for
the filter of the heater electric components
is activated.
[Ext ERR]
Lights up when an external input signal
stops the heater.
Status
Time
[SD CARD ERR]
Lights up when the SD card is missing,
broken, or when its cover is opened.
[VERSION ERR]
Lights up when the main PLC unit and
touch panel versions do not match.
[PLC BATT ERR]
Lights up when an internal battery error
occurs in the main PLC unit.
* You need to reconfigure the parameters,
as they are reset after you replace the
battery.
[TEMP CTRL1/2 ERR]
Lights up when an error occurs in the
temperature control unit.
2-21