Setting Menu List

• Some of the following setting items can also be set from the printer side.
Function name
Coloring temperature setting
Standby temperature setting
Temperature display setting
Automatic OFF time setting
Time after filter cleaning
Time after filter replacement
External input setting
External output setting
Clear log
Backlight setting
*1 Transition to standby is only from the printer.
*2 Heater is not turned off while printing locally.
*3 Value can not be set, only time can be cleared

Setting color fixing temperature

Estimation of temperature setting
The color fixing temperature is based on 180 °C and should be adjusted according to the nature of the media to be used.
Set higher temp
Color development
Uncolored (dull color)
Stain
Media shrinkage
Resolution (pass)
Low pass mode
Media thickness
Thick media
Set the color fixing temperature
1
Touch the display temperature of [SV] on the top screen.
2
Set the color fixing temperature
• Setting range:150.0 ~ 200.0 °C
Set from
Set value
printer
~
~
150.0
180.0
200.0
Yes
~
~
100.0
120.0
150.0
Yes
● Celsius(
°C
)
○ Fahrenheit(
°F
)
1
~
5
~
60(min)
Yes
300(H)
2000(H)
○ ON
● OFF
○ ON
● OFF
○ Enable
● Disable
~
~
1
10
60
Set lower temp
Many stains
Shrinking is large
High pass mode
Thin media
Chapter 2 Basic Operation
Overview
Set the temperature at color development.
16/5000
Set the temperature at standby.*1
Select the display of current temperature and set
temperature of heater from Celsius, Fahrenheit.
Local
:Set the time to turn off the heater after
transition to Ready. * 2
Remote:Set the time from the end of printing to
turning OFF.
Set the time until the alert is issued after cleaning
the filter. * 3
Time until alert comes out after filter exchange * 3
External input setting
Set whether or not to turn off the heater from
external input.
External output setting
Set whether to output no-voltage contact during
heater ON.
Clear event and error log.
Set backlight auto OFF.
Set whether to turn the backlight OFF or not when
the heater is off.
Set the time for turning OFF.
Remarks
Depending on the media characteristics, media may shrink
by 2% when coloring.
When the high pass is set, the time in the furnace
becomes long, so set the set temperature low.
Please set the temperature high for thick (high density)
media.