Extension Cable Specifications - Mitsubishi Electric Q26UD(E)HCPU User Manual

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

3.
When plugging the extension cable to any base unit, hold the connector part of the extension
cable.
4.
After fitting the extension cable, always tighten the extension cable connector fixing screws.
(Tightening torque: 0.20N•m)
(3) Disconnection of extension cable
When disconnection the extension cable, hold and pull the connector part of the extension cable after confirming
that the fixing screws have been completely removed.
4.3.3

Extension cable specifications

The extension cables are connected to transfer signals between a main base unit and an extension base unit or
between extension base units.
Item
Cable length
Conductor resistance value
Weight
When the extension cables are used in combination, overall distance of the combined cable must be 13.2m or less.
Main base unit
Connector
Extension cable
Fixing screw
Flat blade screwdriver
QC05B
QC06B
0.45m
0.6m
0.044
0.051
0.15kg
0.16kg
CHAPTER 4 INSTALLATION AND WIRING
Main base unit
Type
QC12B
QC30B
1.2m
3.0m
0.082
0.172
0.22kg
0.40kg
QC50B
QC100B
5.0m
10.0m
0.273
0.530
0.60kg
1.11kg
87