Number
Name
OFF: Refresh arrival
All stations refresh
SM254
command
ON: Refresh all
OFF: Operative
SM255
ON: Standby network
MELSECNET/10,
OFF: Reads
SM256
MELSECNET/H
ON: Does not read
module 1
information
OFF: Writes
SM257
ON: Does not write
OFF: Operative
SM260
ON: Standby network
MELSECNET/10,
OFF: Reads
SM261
MELSECNET/H
ON: Does not read
module 2
information
OFF: Writes
SM262
ON: Does not write
OFF: Operative
SM265
ON: Standby network
MELSECNET/10,
OFF: Reads
MELSECNET/H
SM266
ON: Does not read
module 3
information
OFF: Writes
SM267
ON: Does not write
OFF: Operative
SM270
ON: Standby network
MELSECNET/10,
OFF: Reads
SM271
MELSECNET/H
ON: Does not read
module 4
information
OFF: Writes
SM272
ON: Does not write
Meaning
Explanation
• Effective for the batch refresh (also
effective for the low speed cyclic)
• Designate whether to receive arrival
stations only or to receive all slave
stations in the MELSECNET/H.
• Effective for the batch refresh (also
effective for the low speed cyclic)
• Designate whether to receive arrival
station
stations only or to receive all slave
stations in the CC-Link IE Controller
stations
Network.
• Effective for the batch refresh (also
effective for the low speed cyclic)
• Specify whether to receive only arrival
station or all stations in the
MELSECNET/H or CC-Link IE
Controller Network.
Turns on when it belongs to the standby
network
network. (If no specification has been
made, it is set to the operative network.)
For refresh from the network module to
the CPU module, set whether to read
data from the network module to a device
(such as B and W) or not.
For refresh from the CPU module to the
network module, set whether to write
data in a device (such as B and W) to the
network module or not.
Turns on when it belongs to the standby
network
network. (If no specification has been
made, it is set to the operative network.)
For refresh from the network module to
the CPU module, set whether to read
data from the network module to a device
(such as B and W) or not.
For refresh from the CPU module to the
network module, set whether to write
data in a device (such as B and W) to the
network module or not.
Turns on when it belongs to the standby
network
network. (If no specification has been
made, it is set to the operative network.)
For refresh from the network module to
the CPU module, set whether to read
data from the network module to a device
(such as B and W) or not.
For refresh from the CPU module to the
network module, set whether to write
data in a device (such as B and W) to the
network module or not.
Turns on when it belongs to the standby
network
network. (If no specification has been
made, it is set to the operative network.)
For refresh from the network module to
the CPU module, set whether to read
data from the network module to a device
(such as B and W) or not.
For refresh from the CPU module to the
network module, set whether to write
data in a device (such as B and W) to the
network module or not.
Corresponding
Set by
Corresponding
ACPU
(When Set)
M9
U
New
S (Initial)
New
U
S (Initial)
New
U
S (Initial)
New
U
S (Initial)
New
U
APPENDICES
A
CPU
Qn(H)
QnPH
QnPRH
*2
Qn(H)
QnPH
QnPRH
QnU
Qn(H)
QnPH
QnPRH
Qn(H)
QnPH
QnPRH
Qn(H)
QnPH
QnPRH
Qn(H)
QnPH
QnPRH