Mitsubishi Electric Q26UD(E)HCPU User Manual page 479

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

*1
Universal model QCPU except the Q00UJCPU
*2
Built-in Ethernet port LCPU whose serial number (first five digits) is "16072" or later
(9) Latch area
Number
Name
Backup error check
OFF: No error
SM916
flag
ON: Error
Restoration error
OFF: No error
SM922
check flag
ON: Error
Upper limit setting
OFF: Backup continued
SM923
flag for the number
ON: Backup stopped
of backup data
OFF: Retry not
Automatic backup
SM924
retry failure flag
ON: Retry failed
Data logging error
OFF: No error
SM960
check flag
ON: Error
*1
Modules whose serial number (first five digits) is "17103" or later
*2
The LCPU, except the L02SCPU and L02SCPU-P, whose serial number (first five digits) is "17102" or later
*3
Modules whose serial number (first five digits) is "18052" or later
(10)Conversion from A series to Q or L series
The special relay (M9000 to M9255) for ACPU corresponds to the special relay (SM1000 to SM1255) for QCPU
or LCPU after the A to Q/L conversion. (Note that the Basic model QCPU and Redundant CPU do not support the
A to Q/L conversion.) All bits in this area of the special relay are turned on or off by system (cannot be turned on
or off by user using a program). To turn on or off the bit by user, correct the program using the special relay for
QCPU or LCPU. The special relay (M9084, M9200 to M9255), however, includes the areas that can be turned on
or off by user. For those areas, the bit can be turned on or off by user in the converted special relay (SM1084,
SM1200 to SM1255) as well. For details on the special relay for ACPU, refer to the following.
User's manual for the CPU module used
Type MELSECNET, MELSECNET/B Data Link System Reference Manual
Meaning
Explanation
This relay turns on if an error occurs at
the execution of backup of the CPU
module. This relay turns off at the start of
backup.
This relay turns on if an error occurs at
the execution of restoration of the CPU
module. This relay turns off at the start of
backup.
This relay specifies the operation of
backup when the number of backup data
reaches the upper limit. (Valid only when
bit5 of SD944 is on)
OFF: After deleting the oldest date stamp
folder, the backup is continued.
ON: The backup is not continued if the
upper limit of the number of backup data
is exceeded. (In this case, the backup is
completed with an error.)
This relay turns on when the retry of the
automatic backup is failed even after the
executed/Retry
specified number of retries are
being executed
attempted, and turns off at the start of the
automatic backup. (This relay does not
turn off when SM1926 is on.)
This relay turns on if an error occurs
during the execution of data logging. This
relay turns off when the data logging is
restarted by turning on SM1938 (Data
logging restart flag at error stop) or is
started or stopped by using the CPU
Module Logging Configuration Tool.
Corresponding
Set by
Corresponding
ACPU
(When Set)
M9
S (Status
New
change)
S (Status
New
change)
U
New
S (Status
New
change)
S (Error)
New
APPENDICES
A
CPU
*1
QnUDV
*1
QnUDV
*3
QnUDV
*3
QnUDV
*1
QnUDV
*2
LCPU
477