Mitsubishi Electric Q26UD(E)HCPU User Manual page 483

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

ACPU
Special
Special
Special
Relay after
Relay after
Relay
Conversion
Modification
M9043
SM1043
SM805
M9045
SM1045
M9046
SM1046
SM802
M9047
SM1047
SM801
M9049
SM1049
SM701
M9051
SM1051
M9052
SM1052
M9056
SM1056
M9057
SM1057
M9058
SM1058
M9059
SM1059
M9060
SM1060
M9061
SM1061
M9070
SM1070
M9084
SM1084
Name
Meaning
OFF: Sampling trace in
Sampling trace
progress
completed
ON: Sampling trace
completed
Watchdog timer
OFF: Does not reset WDT
(WDT) reset
ON: Resets WDT
OFF: Trace not in
Sampling trace
progress
ON: Trace in progress
OFF: Sampling trace
Sampling trace
suspended
preparations
ON: Sampling trace
started
Number of
OFF: Output until NULL
output
code encountered
characters
ON: 16 characters output
selection
CHG instruction
OFF: Enabled
execution
ON: Disable
disable
OFF: 7-SEG segment
SEG instruction
display
switch
ON: I/O partial refresh
OFF: Other than when P, I
Main side P, I
set being requested
set request
ON: P, I set being
requested
OFF: Other than when P, I
Sub side P, I set
set being requested
request
ON: P, I set being
requested
Main side P, I
Momentarily ON at P, I set
set completion
completion
Sub program P, I
Momentarily ON at P, I set
set completion
completion
OFF: Other than when P, I
Sub program 2
set being requested
P, I set request
ON: P, I set being
requested
OFF: Other than when P, I
Sub program 3
set being requested
P, I set request
ON: P, I set being
requested
OFF: Read time not
A8UPU/A8PUJ
shortened
required search
ON: Read time
*3
time
shortened
OFF: Error check
Error check
executed
ON: No error check
Details
This relay turns on after execution of the
TRACE instruction and upon completion of
sampling trace performed the number of
times preset by the parameter. Reset when
TRACER instruction is executed.
If SM1045 is turned on, the watchdog timer
is reset when the ZCOM instruction and
batch processing of data communication
requests are executed. (Use this when
scan time exceeds 200ms.)
This relay is on during execution of
sampling trace.
Sampling trace is not executed unless
SM1047 is turned ON. Sampling trace is
cancelled when SM1047 turns off.
• When SM1049 is off, characters up to
NULL (00
) code are output.
H
• When SM1049 is ON, ASCII codes of 16
characters are output.
• Switched ON to disable the CHG
instruction.
• Turn this on when requesting program
transfer. It is automatically turned off
upon completion of the transfer.
When SM1052 is on, the SEG instruction is
used as an I/O part refresh instruction.
When SM1052 is off, the SEG instruction is
used as a 7-SEG display instruction.
While a program is running, upon
completion of transfer of another program
(for example, a subprogram when the main
program is running), a P and I set request
is turned on. This relay automatically turns
off upon completion of P and I setting.
This relay turns on for a moment upon
completion of P and I setting, and
immediately turns off.
While a program is running, upon
completion of transfer of another program
(for example, a subprogram when the main
program is running), a P and I set request
is turned on. This relay automatically turns
off upon completion of P and I setting.
When this is turned on, the search time in
the A8UPU/A8PUJ can be shortened. (In
this case, the scan time is extended by
10%.)
This relay sets whether or not to check the
following errors at the time of the END
instruction processing (for setting of the
END instruction processing time).
• Check for fuse blown
• Check of battery
• Collation check of I/O module
APPENDICES
Corresponding
A
CPU
Qn(H)
QnPH
*1
QnU
LCPU
Qn(H)
QnPH
Qn(H)
QnPH
*1
QnU
LCPU
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
481

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents