Number
Name
SM280
CC-Link error
Mounting status of
SM310
RS-232, RS-
442/485 adapter
Communication
reserved time
SM315
delay
enable/disable flag
Automatic CC-Link
SM319
start
Presence/absence
SM320
of SFC program
Start/stop SFC
SM321
program
SFC program start
SM322
status
462
Meaning
This relay turns on if a CC-Link error is
OFF: Normal
detected in any of the CC-Link modules
ON: Error
mounted, and turns off when the
condition returns to normal.
This relay stores whether the RS-232 or
RS-422/485 adapter is mounted or not.
OFF: No adapter
The mounting status of the RS-232 or
mounted
RS-422/485 adapter is checked during
ON: RS-232 or RS-
the initial processing, and if it is mounted,
422/485 adapter
this relay turns on.
mounted
The on/off status set during the initial
processing is held until the CPU module
is powered off and on again or is reset.
• This flag is enabled when the time
reserved for communication
processing is set in SD315.
• Turns ON to delay the END processing
by the time set in SD315 in order to
perform communication processing.
OFF: Without delay
(The scan time increases by the period
ON: With delay
set in SD315.)
• Turns OFF to perform the END
processing without a delay of the time
set in SD315 when there is no
communication processing. (Defaults
to OFF)
• This relay indicates whether the CC-
Link module is started and all the data
are refreshed by the automatic CC-
Link start function.
• This relay is on when all the data are
refreshed by the automatic CC-Link
OFF: Not activated
start function.
ON: Activated
• Then the automatic CC-Link start
function is not activated, or when the
refresh device range is insufficient, this
relay is turned off. (If the refresh device
range set for the automatic CC-Link
start function is insufficient, all of the
refresh is stopped.)
OFF: SFC program
• This relay is on if an SFC program is
absent
registered.
ON: SFC program
• This relay turns off if no SFC program
present
is registered.
• The same value as in SM320 is set as
the initial value. (This relay turns on
OFF: SFC program not
when an SFC program is registered.)
executed (stop)
• Turning off this relay stops SFC
ON: SFC program
program execution.
executed (start)
• Turning on this relay restarts SFC
program execution.
In the SFC tab of "PLC Parameter",
"Initial start" is set for "SFC program start
OFF: Initial start
mode".
ON: Resume start
• At initial start:OFF
• At continued start:ON
Set by
Explanation
(When Set)
S (Status
change)
S (Initial)
S (Initial
processing
and status
change)
S (Initial)
S (Initial)/U
S (Initial)/U
Corresponding
Corresponding
ACPU
M9
New
New
U
New
Q00J/Q00/Q01
New
Q00J/Q00/Q01
M9100
Q00J/Q00/Q01
M9101 format
change
Q00J/Q00/Q01
M9102 format
change
CPU
Qn(H)
QnPH
QnPRH
LCPU
LCPU
*1
Qn(H)
QnPH
QnPRH
QnU
LCPU
*1
Qn(H)
QnPH
QnPRH
QnU
LCPU
*1
Qn(H)
QnPH
QnPRH
QnU