Number
Name
Meaning
CH1 counter
CH1 counter
SD1885
type monitor
type monitor
CH1 selected
CH1 selected
SD1886
counter
counter
function
function
CH1 error
CH1 error
SD1887
code
code
CH1 warning
CH1 warning
SD1888
code
code
SD1900,
CH2 current
CH2 current
SD1901
value
value
CH2 status
CH2 status
SD1902
monitor
monitor
596
Explanation
This register stores a value indicating the counter type for
high-speed counter of CH1 set by the parameter.
Counter selection is disabled (fixed at "0") when a value
stored to CH1 operation mode monitor (SD1884) is other
than "1" (normal mode).
• 0: Linear counter
• 1: Ring counter
This register stores a value indicating the selected counter
function for high-speed counter of CH1 set by the parameter.
Counter selection is disabled (fixed at "0") when a value
stored to CH1 operation mode monitor (SD1884) is other
than "1" (normal mode).
• 0: Count disabling function
• 1: Latch counter function
• 2: Sampling counter function
• 3: Count disabling/preset function
• 4: Latch counter/preset function
This register stores the error code of an error occurred in
CH1.
This register stores the warning code of a warning occurred
in CH1.
• This register stores the current counter value of CH2 at
END processing.
• When the ICCNTRD2 instruction is executed, this register
is updated by the current value at that moment.
The current value is updated at END processing and by the
ICCNTRD2 instruction only when Normal Mode is set for
Operation Mode Setting (high-speed counter function
parameter). The range of a value that can be read is from -
2147483648 to 2147483647.
This register stores each status of CH2.
b15
to
b8
b7
b6
b5
b4
b3
b2 b1 b0
0
0/1
0/1
0/1 0/1 0/1 0/1 0/1 0/1
Set by
(When Set)
S (Every
END
processing)
S (Every
END
processing)
S (Every
END
processing)
S (Every
END
processing)
S (Every
END
processing/
Instruction
execution)
Addition/subtraction
0: Addition
1: Subtraction
Underflow detection flag
0: Not detected
1: Detected
Overflow detection flag
0: Not detected
1: Detected
S (Every
Sampling flag
END
0: Not operating
processing)
1: Operating
Frequency
measurement flag
0: Not operating
1: Operating
Rotation speed
measurement flag
0: Not operating
1: Operating
Pulse measurement flag
0: Not operating
1: Operating
PWM output flag
0: Not operating
1: Operating
Fixed to 0.