(b) When the High Performance model QCPU or Process CPU is used
Product
CC-Link IE Controller Network
*1
module
MELSECNET/H module
Ethernet module
CC-Link module
MELSECNET/MINI-S3 data link
*3
module
AnS Series special function
*3
module
Interrupt module
High speed data logger module
High speed data communication
*7
module
GOT
*1
Only the High Performance model QCPU whose serial number (first five digits) is "09012" or later and Process CPU
whose serial number (first five digits) is "10042" or later can be used.
*2
One CPU module can control the following number of modules by setting CC-Link network parameters in a programming
tool.
• CPU modules whose serial number (first five digits) is "08031" or earlier: up to 4 modules
• CPU modules whose serial number (first five digits) is "08032" or later: up to 8 modules
There is no restriction on the number of modules when the parameters are set with the CC-Link dedicated instructions.
For the CC-Link system master/local modules whose parameters can be set by the dedicated instructions, refer to the
following.
MELSEC-Q CC-Link System Master/Local Module User's Manual
*3
The module is available only when the High Performance model QCPU is used.
*4
For the available GOT models, refer to the following.
GOT-A900 Series User's Manual (GT Works2 Version2/GT Designer2 Version2 Compatible Connection System
Manual)
GOT1000 Series Connection Manual (Mitsubishi Products) for GT Works3
GOT2000 Series Connection Manual (Mitsubishi Products) For GT Works3 Version1
*5
The module is available only when the interrupt module is selected by setting the function selector switch (SW2) to OFF.
*6
One module can be mounted for one control CPU.
*7
The function version of the High-Performance model QCPU must be B or later.
40
Model
• QJ71GP21-SX
• QJ71GP21S-SX
• QJ71LP21
• QJ71BR11
• QJ71LP21-25
• QJ71LP21S-25
• QJ71LP21G
• QJ71LP21GE
• QJ71NT11B
• QJ71E71
• QJ71E71-B2
• QJ71E71-B5
• QJ71E71-100
• QJ61BT11
• QJ61BT11N
• A1SJ71PT32-S3
• A1SJ71T32-S3
• A1SD51S
• A1SD21-S1
• A1SJ71J92-S3(When using GET/PUT service)
• A1SJ71AP23Q
• A1SJ71AR23Q
• A1SJ71AT23BQ
*3
• A1SI61
• QI60
*5
• QX40H
*5
• QX70H
*5
• QX80H
*5
• QX90H
• QD81DL96
• QJ71DC96
• GOT-A900 Series (only for bus connection)
• GOT1000 Series (only for bus connection)
• GOT2000 Series (for bus connection only)
Maximum number of modules/units
per system
Up to 2 modules
Up to 4 modules
Up to 4 modules
*2
No restriction
No restriction
(Auto refresh setting not allowed)
Up to 6 modules in total
Only 1 module
*6
Only 1 module
*6
Only 1 module
*4
*4
Up to 5 units
*4
Up to 4 modules in
total