To use the converted special relay in the High Performance model QCPU, Process CPU, Universal model QCPU, or LCPU,
check "Use special relay/special register from SM/SD1000" under "A-PLC Compatibility Setting".
Project window  [Parameter]  [PLC Parameter]  [PLC System]
Note that the processing time will increase when the converted special relay is used.
[How to read the Special Relay for Modification column]
• If the special relay number for QCPU or LCPU is provided, correct the program using it.
•  means that the converted special relay can be used.
•  means that the special relay cannot be used in QCPU or LCPU.
ACPU
Special
Special
Special
Relay after
Relay after
Relay
Conversion
Modification
M9000
SM1000
M9002
SM1002
M9005
SM1005
M9006
SM1006
M9007
SM1007
M9008
SM1008
SM1
M9009
SM1009
SM62
478
Name
OFF: Normal
Fuse blown
ON: Module with blown
I/O module
OFF: Normal
verify error
ON: Error
OFF: AC DOWN not
AC DOWN
detection
ON: AC DOWN detected
OFF: Normal
Battery low
ON: Battery low
OFF: Normal
Battery low latch
ON: Battery low
Self-diagnostic
OFF: No error
error
ON: Error
OFF: No F number
Annunciator
detection
ON: F number detected
Meaning
• This relay turns on if there is at least one
output module whose fuse has blown.
• This relay remains on even after the
system returns to normal.
fuse
• Output modules on remote I/O stations
are also checked.
• This relay turns on if the status of the I/O
module differs from that registered at
power-on.
• This relay remains on even after the
system returns to normal.
• I/O modules on remote I/O stations are
also checked.
• This relay is reset only when SD1116 to
SD1123 are reset.
• This relay turns on if a momentary power
failure within 20ms occurs during use of
an AC power supply module.
• This relay is reset when the CPU module
is powered off and then on.
• This relay turns on if a momentary power
failure within 10ms occurs when using an
detected
AC power supply module.
• This relay is reset when the CPU module
is powered off and then on.
• This relay turns on if a momentary power
failure within 10ms occurs during use of
a DC power supply module.
• This relay is reset when the CPU module
is powered off and then on.
• This relay turns on when the battery
voltage drops to or below the specified.
• It turns off when the battery voltage
returns to normal.
• This relay turns on when the battery
voltage drops to or below the specified.
• This relay remains on even after the
battery voltage returns to normal.
This relay turns on if an error is detected by
self-diagnostics.
• This relay turns on when the OUT F or
SET F instruction is executed.
detected
• It turns off when the SD1124 value is
cleared to zero.
Corresponding
Details
LCPU
CPU
Qn(H)
QnPH
*1
QnU
*4
Qn(H)
QnPH
*1
QnU
LCPU
Qn(H)
QnPH
*1
QnU
LCPU
Qn(H)
QnPH
*1
QnU
LCPU
Qn(H)
QnPH
*1
QnU
LCPU
Qn(H)
QnPH
*1
QnU
LCPU
Qn(H)
QnPH
*1
QnU
LCPU
Qn(H)
QnPH
*1
QnU
LCPU

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents