Mitsubishi Electric Q26UD(E)HCPU User Manual page 484

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

ACPU
Special
Special
Special
Relay after
Relay after
Relay
Conversion
Modification
M9091
SM1091
M9100
SM1100
SM320
M9101
SM1101
SM321
M9102
SM1102
SM322
M9103
SM1103
SM323
M9104
SM1104
SM324
M9108
SM1108
SM90
M9109
SM1109
SM91
M9110
SM1110
SM92
M9111
SM1111
SM93
M9112
SM1112
SM94
M9113
SM1113
SM95
M9114
SM1114
SM96
482
Name
Operation error
OFF: No error
details flag
ON: Error
OFF: SFC program
Presence/absen
ce of SFC
ON: SFC program
program
Start/stop SFC
OFF: SFC programs stop
program
ON: SFC programs start
SFC program
OFF: Initial start
start status
ON: Resume start
OFF: Continuous
Presence/absen
ce of continuous
transition
ON: Continuous
Continuous
OFF: When transition is
transition
prevention flag
ON: When no transition
Step transition
monitoring timer
start (equivalent
of SD90)
Step transition
monitoring timer
start (equivalent
of SD91)
Step transition
monitoring timer
start (equivalent
of SD92)
Step transition
OFF: Monitoring timer
monitoring timer
start (equivalent
ON: Monitoring timer
of SD93)
Step transition
monitoring timer
start (equivalent
of SD94)
Step transition
monitoring timer
start (equivalent
of SD95)
Step transition
monitoring timer
start (equivalent
of SD96)
Meaning
• This relay turns on when the detail factor
of the operation error is stored into
SD1091.
• This relay remains on even after the
condition returns to normal.
This relay is on when an SFC program has
absent
been registered, and is off when no
program is registered.
present
• The same value as in SM1100 is set as
the initial value. (This relay turns on
when an SFC program is registered.)
• This relay is turned off to stop SFC
program execution.
• This relay is turned on to resume the
SFC program execution.
In the SFC tab of "PLC parameter", "Initial
start" is set for "SFC program start mode".
• At initial start:OFF
• At continued start:ON
Set whether to enable or disable
transition not
continuous transition for the blocks where
effective
"continuous transition bit" of the SFC
information device is not set.
transition effective
• This relay is off while the module is in the
continuous transition mode or during
continuous transition, and is on when
executed
continuous transition is not executed.
• This relay is always on while the CPU
module is operating not in the continuous
transition mode.
The relay turns on when measurement by
reset
the step transition monitoring timer is
started. The step transition monitoring timer
reset start
is reset when the relay turns off.
Corresponding
Details
CPU
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH
Qn(H)
QnPH